3.2 Nominal data

Motor

M1G045-BE

Nominal voltage / VDC

24

Nominal voltage
range / VDC

16 .. 28

Speed (rpm) / min

-1

4060

Power consumption / W

26

Current draw / A

1.2

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

50

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

0.5 kg

Size

120 mm

Motor size

45

Rotor surface

Galvanized

Impeller material

PA plastic

Number of blades

9

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP20

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0 - dry environment

Installation position

Any

Condensation
drainage holes

None

Mode

S1

Motor mounting

Ball bearing

Technical features

- Tach output
- Soft start
- Reverse polarity protection

Electrical hookup

Plug

Motor protection

Reverse polarity and locked-rotor
protection

with cable

Axial

Protection class

I (if the protective earth is connected by
the customer to the marked PE
connection point)

Conformity with
standards

EN 60950-1

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing

Strength class of
screws

8.8

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 55533-5-9970 · ENU · Change 89917 · Approved 2018-01-08 · Page 6 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R1G120-AD13-13

Page 1: ...authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basi...

Page 2: ...parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotat...

Page 3: ...proper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant...

Page 4: ...ivery 2 Max clearance for screw 4 mm 3 Max clearance for screw 4 mm 4 Cable PVC AWG20 4 pole connector housing TE 925075 7 3x plug pin TE 163555 8 4 1 Tach white 4 2 not used 4 3 UN 24 VDC red 4 4 GND...

Page 5: ...ensions in mm Accessory part inlet ring 96120 2 4013 not included in scope of delivery Item no 55533 5 9970 ENU Change 89917 Approved 2018 01 08 Page 5 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D...

Page 6: ...of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Information on surface quality The surfaces of the pr...

Page 7: ...ll pole disconnection switch When working on the fan secure the system machine in which the fan is installed so as to prevent it from being switched back on NOTE Water ingress into wires or cables Wat...

Page 8: ...ting instructions 4 5 Connection diagram Drawing preliminary Item no 55533 5 9970 ENU Change 89917 Approved 2018 01 08 Page 8 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0...

Page 9: ...t the supply line s main switch 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live te...

Page 10: ...products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassembly Disassembly of the product must be performed or superv...

Reviews: