3.2 Nominal data

Motor

M2E068-BF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Method of obtaining
data

fc

fc

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

2250

2300

Power consumption / W

58

70

Current draw / A

0.26

0.31

Capacitor / µF

1.5

1.5

Capacitor voltage / VDB

400

400

Capacitor standard

S0 (CE)

S0 (CE)

Min. ambient
temperature / °C

-25

-25

Max. ambient
temperature / °C

45

50

Min. temp. of flow
medium / °C

0

0

Max. temp. of flow
medium / °C

40

40

Flow quantity / m

3

/h

0.71

0.74

Max. flow head / m

6.1

7.2

ml = Max. load · me = Max. efficiency · fc = Free-conveying

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1.6 kg

Motor size

68

Rotor surface

Painted black

Terminal box material

Glass-fiber reinforced plastic

Pump impeller
material

Glass-fiber reinforced plastic

Agitator material

PE

Pump housing
material

Glass-fiber reinforced plastic

Cross-member material

Glass-fiber reinforced plastic

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP44

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H1+

Installation position

Vertical

Condensation
drainage holes

On stator side

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Electrical hookup

Connector with cable; Via terminal box,
capacitor integrated and connected

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Lateral

Protection class

I (with customer connection of protective
earth)

Motor capacitor
according to EN 60252-
1 in safety protection
class

S0

Conformity with
standards

EN 60335-1; CE

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

-40 °C

Item no. 10041-5-9970 · ENU · Change 202174 · Approved 2018-12-28 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for P2E070-AA26-01

Page 1: ...otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electric...

Page 2: ...ing device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device Injuries can result Do not wear any loose fitting or dangling clothing or je...

Page 3: ...ominal data Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operation in medical equipment with a life s...

Page 4: ...oduct drawing All dimensions in mm 1 Max immersion depth 2 Pressure tap 3 Intake 4 3x crimped splices Item no 10041 5 9970 ENU Change 202174 Approved 2018 12 28 Page 4 9 ebm papst Mulfingen GmbH Co KG...

Page 5: ...nternally connected with cable Lateral Protection class I with customer connection of protective earth Motor capacitor according to EN 60252 1 in safety protection class S0 Conformity with standards E...

Page 6: ...ements Check whether the information on the nameplate matches the connection data If the motor run capacitor was not installed by ebm papst check whether the information on the motor run capacitor mat...

Page 7: ...instructions 4 3 Connection diagram L blue N black PE green yellow Item no 10041 5 9970 ENU Change 202174 Approved 2018 12 28 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phon...

Page 8: ...s Send the pump to the manufacturer for repair or replacement WARNING Live terminals and connections even with device switched off Electric shock Wait five minutes after disconnecting the voltage at a...

Page 9: ...legal requirements Always observe the applicable country specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding...

Reviews: