ebm-papst M4E068-EC03-01 Operating Instructions Manual Download Page 5

Operating instructions

M4E068-EC03-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M4E068-EC

Phase

1~

Nominal voltage / VAC

230

Frequency / Hz

50

Method of obtaining
data

me

Valid for approval/
standard

CE

Speed (rpm) / min

-1

1250

Power consumption / W

130

Power output / W

65

Current draw / A

0.6

Rated torque / Ncm

50

Mean starting torque
/ Ncm

40

Capacitor / µF

5

Capacitor voltage / VDB

450

Capacitor standard

S0 (CE)

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

30

Starting current / A

0.77

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

2.1 kg

Motor size

68

Rotor surface

Painted black

Direction of rotation

Right and left

Degree of protection

IP00

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0 - dry environment

Installation position

Any

Condensation
drainage holes

None, open rotor

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 60335-1; EN 60034-1; EN 60204-1

Approval

EAC

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

Strength class of
screws

8.8

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 17029-5-9970 · ENU · Change 212910 · Approved 2020-02-21 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for M4E068-EC03-01

Page 1: ...stalled operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and...

Page 2: ...inal packaging in a clean environment Protect the device against environmental effects and dirt until final installation We recommend storing the device for no longer than one year in order to guarant...

Page 3: ...ns Operation with completely or partially disassembled or manipulated protective devices In addition all applications not listed among the intended uses Item no 17029 5 9970 ENU Change 212910 Approved...

Page 4: ...Product drawing All dimensions in mm 1 Max clearance for screw 5 mm 2 Cable PVC 4G 0 5 mm 4x splice Item no 17029 5 9970 ENU Change 212910 Approved 2020 02 21 Page 4 10 ebm papst Mulfingen GmbH Co KG...

Page 5: ...designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Information on surface quality...

Page 6: ...g the cross section note the sizing criteria according to EN 61800 5 1 The protective earth must have a cross section equal to or greater than that of the phase conductor We recommend the use of 105 C...

Page 7: ...any automatic overheating protection The device can become hot and catch fire For the version without thermal overload protector also install a suitable motor protection switch Item no 17029 5 9970 EN...

Page 8: ...nstructions 4 4 Connection diagram U1 blue Z brown U2 gray N black Item no 17029 5 9970 ENU Change 212910 Approved 2020 02 21 Page 8 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Pho...

Page 9: ...t if imbalance persists after cleaning Motor not turning Mechanical blockage Switch off isolate from supply and remove mechanical blockage Line voltage faulty Check line voltage restore power supply F...

Page 10: ...num Non ferrous metal e g motor windings Plastics particularly with brominated flame retardants in accordance with marking Insulating materials Cables and wires Electronic scrap e g circuit boards Onl...

Page 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information ebm papst M4E068 EC03 01...