Operating instructions
M2E068-EC07-18
Translation of the original operating instructions
3.2 Nominal data
Motor
M2E068-EC
Phase
1~
Nominal voltage / VAC
208
Frequency / Hz
60
Method of obtaining
data
me
Valid for approval/
standard
CE/UL
Speed (rpm) / min
-1
2800
Power consumption / W
220
Power output / W
110
Current draw / A
1.10
Rated torque / Ncm
37
Mean starting torque
/ Ncm
21
Capacitor / µF
6
Capacitor voltage / VDB
400
Capacitor standard
S2 (CE)
Max. ambient
temperature / °C
-
Starting current / A
1.55
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
2.2 kg
Fan size
68 mm
Rotor surface
Rotor open, painted black
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP10
Insulation class
"F"
Moisture (F) /
Environmental (H)
protection class
H0 - dry environment
Installation position
Any
Condensation
drainage holes
None, open rotor
Mode
S1
Motor bearing
Ball bearing
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP)
internally connected
Protection class
I (with customer connection of protective
earth)
Conformity with
standards
EN 60335-1; CE
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
3.4 Mounting data
For screw clearance, see Chapter 3.1 Product drawing
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Strength class of
screws
8.8
Any further mounting data required can be taken from the product drawing.
3.5 Transport and storage conditions
;
Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
+ 80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
- 40 °C
4. CONNECTION AND STARTUP
4.1 Mechanical connection
WARNING
Hot motor housing
Risk of fire
→ Ensure that no combustible or flammable materials are
located close to the motor.
CAUTION
Cutting and crushing hazard when removing motor from
packaging
→ Carefully remove the device from its packaging. Strictly
avoid shocks.
→ Wear safety shoes and cut-resistant safety gloves.
;
Check the device for transport damage. Damaged devices are not to
be installed.
;
Install the undamaged device in accordance with your application.
CAUTION
Possible damage to the device
If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of
installation until all fastening screws have been tightened.
Item no. 14441-5-9970 · ENU · Change 89188 · Approved 2016-08-25 · Page 4 / 8
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com