3.2 Nominal data
Motor
M2E068-BF
Phase
1~
1~
Nominal voltage / VAC
240
240
Nominal voltage
range / VAC
220 .. 240
220 .. 240
Frequency / Hz
50
60
Method of obtaining
data
me
me
Valid for approval/
standard
CE
CE
Speed (rpm) / min
-1
2400
2600
Power consumption / W
51
62
Power output / W
20
23
Current draw / A
0.22
0.26
Capacitor / µF
1
1
Capacitor voltage / VDB
450
450
Capacitor standard
S0 (CE)
S0 (CE)
Min. ambient
temperature / °C
-25
-25
Max. ambient
temperature / °C
50
50
Starting current / A
0.3
0.3
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
1.033 kg
Motor size
68
Rotor surface
Painted black
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP44; installation- and position-dependent
Insulation class
"B"
Moisture (F) /
Environmental (H)
protection class
H0 - dry environment
Installation position
Any
Condensation
drainage holes
None
Mode
S1
Motor bearing
Ball bearing
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Conformity with
standards
EN 60335-1; CE
Approval
CCC; EAC
;
Use the device in accordance with its degree of protection.
Information on surface quality
The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. The product is to be protected against UV radiation to
prevent the formation of patches and fading. Changes in color are not a
reason for complaint and are not covered by the warranty. UV radiation
in the frequency range and the intensity of natural solar radiation has no
effect on the technical properties of the products.
3.4 Mounting data
Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.
Strength class of
screws
8.8
For screw clearance, see Chapter 3.1 Product drawing
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
3.5 Transport and storage conditions
Max. permitted
ambient temp. for
motor (transport/
storage)
- 40 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
+ 80 °C
Item no. 16226-5-9970 · ENU · Change 230616 · Approved 2022-03-15 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com