ebm-papst K4E146-AB73-21 Operating Instructions Manual Download Page 4

Operating instructions

K4E146-AB73-21

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable ETFE AWG20, 1x plug pin tyco 926886-1, cable ETFE AWG22, 6x plug pin tyco 926886-1, 1x 9-pole connector housing tyco
927231-5

1.1

Step 1 (min.)

1.2

Step 2

1.3

Step 3

1.4

Step 4

1.5

Step 5 (max.)

1.6

-

1.7

-

1.8

N

1.9

Protective earth

2

8x sheet metal nut for thread EN ISO 1478-ST4.8 (min. screw length 14.5 mm plus material thickness of attachment)

Item no. 10429-5-9970 · ENU · Change 202174 · Approved 2018-12-28 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for K4E146-AB73-21

Page 1: ...ed and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the el...

Page 2: ...tact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and...

Page 3: ...ing the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer...

Page 4: ...ector housing tyco 927231 5 1 1 Step 1 min 1 2 Step 2 1 3 Step 3 1 4 Step 4 1 5 Step 5 max 1 6 1 7 1 8 N 1 9 Protective earth 2 8x sheet metal nut for thread EN ISO 1478 ST4 8 min screw length 14 5 mm...

Page 5: ...N 60252 1 in safety protection class S2 Conformity with standards EN 60335 1 CE Approval EAC CCC With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum...

Page 6: ...er ingress at the customer end of the cable can damage the device Make sure the end of the cable is connected in a dry environment Only connect the device to circuits that can be switched off with an...

Page 7: ...nd device 4 3 Plug connection 4 3 1 Making supply connections Check your connector s pin assignment Connect the built in connector with the mating connector Ensure that the connector is properly engag...

Page 8: ...h must interrupt the circuit on switching 1 N blue 2 brown 3 yellow 4 Step I white 5 Step II red 6 Step III gray 7 L1 8 Step IV orange 9 Step V black Item no 10429 5 9970 ENU Change 202174 Approved 20...

Page 9: ...POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switched off Elec...

Page 10: ...quirements Always observe the applicable country specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposa...

Reviews: