ebm-papst K3G310-AX52-05 Operating Instructions Manual Download Page 4

Operating instructions

K3G310-AX52-05

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Inlet nozzle with bleeder connection for pressure relief (k-factor: 116)

2

Connection line AWG 18 with connector housing AMP order no. 1-480 702-0 with 4 x plug pin AMP order no. 926 885-1

2.1

PE (green / yellow)

2.2

L3 (black 3)

2.3

L2 (black 2)

2.4

L1 (black 1)

3

Connection line AWG 18 and AWG 22 with connector housing Phoenix order no. 17 57 05 1

3.1

+10V (red)

3.2

GND (blue)

3.3

0-10V / PWM (yellow)

3.4

Not defined (orange)

3.5

NC - alarm (white1)

3.6

COM - alarm (white 2)

4

Mounting position: shaft horizontal (install the support struts only vertically as shown in the view!) or rotor on bottom; rotor on top on
request

Item no. 50749-5-9970 · Revision 70943 · Release 2011-12-06 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for K3G310-AX52-05

Page 1: ...permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must...

Page 2: ...parts that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstil...

Page 3: ...ng the device with an imbalance e g caused by dirt deposits or icing Operation in medical equipment with a life sustaining or lifesaving function Operation with external vibrations Moving solids conte...

Page 4: ...3 L2 black 2 2 4 L1 black 1 3 Connection line AWG 18 and AWG 22 with connector housing Phoenix order no 17 57 05 1 3 1 10V red 3 2 GND blue 3 3 0 10V PWM yellow 3 4 Not defined orange 3 5 NC alarm wh...

Page 5: ...les Rotor side Operation mode S1 Motor bearing Ball bearing Technical features Output 10 VDC max 10 mA Tach output Alarm relay Integrated PID controller Motor current limit PFC passive RS485 ebmBUS So...

Page 6: ...cting the electrical system DANGER Electric voltage on the device Electric shock Always install a protective earth first Check the protective earth DANGER Incorrect insulation Risk of fatal injury fro...

Page 7: ...ed for compliance with EMC limits interference emission and interference immunity idle currents in the mains cable can be measured even when the motor is at a standstill and the mains voltage is switc...

Page 8: ...10 mA AC1 1 7 NC white 2 Floating status message contact break for failure 2 8 0 10 V yellow Control input set value 0 10 VDC impedance 100 kOhm SELV 2 11 10 V red Voltage output 10 VDC 3 max 10 mA s...

Page 9: ...eration on and off via power supply Switching off the device for maintenance work Switch on the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply...

Page 10: ...ical blockage Mains supply voltage faulty Check mains supply voltage restore power supply Important The error message resets automatically The device starts up again automatically without advance warn...

Page 11: ...ast every 6 months Repair or replacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lin...

Reviews: