ebm-papst K3G225-RD05-03 Operating Instructions Manual Download Page 8

Operating instructions

K3G225-RD05-03

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

No.

Conn.

Designation

Color

Function/assignment

CON10 L

black

Power supply 230 VAC, 50-60 Hz, see nameplate for voltage range

CON11 N

blue

Neutral conductor

CON12 PE

green/
yellow

Protective earth

1

GND

blue

GND connection for control interface

2

0-10V PWM

yellow

Control input 0-10 V or PWM, electrically isolated

3

10 V / max. 1,1
mA

red

Voltage output 10 VDC 1.1 mA, electrically isolated, short-circuit-proof

4

Tacho

white

Tach output: open collector, 1 pulse per revolution, electrically isolated

Item no. 51019-5-9970 · ENU · Change 96553 · Approved 2017-10-26 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for K3G225-RD05-03

Page 1: ...lified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safet...

Page 2: ...Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury...

Page 3: ...ons Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Res...

Page 4: ...dimensions in mm 1 Cable PVC 3G AWG20 3x crimped splices 2 Cable PVC 4x AWG22 4x crimped splices 3 Mounting dimensions Item no 51019 5 9970 ENU Change 96553 Approved 2017 10 26 Page 4 11 ebm papst Mu...

Page 5: ...ve earth Conformity with standards EN 60335 1 CE Approval CCC C22 2 No 77 CAN CSA E60730 1 UL 1004 7 60730 EAC With regard to cyclic speed loads note that the rotating parts of the device are designed...

Page 6: ...prevent it from being switched back on NOTE Water ingress into wires or cables Water ingress at the customer end of the cable can damage the device Make sure the end of the cable is connected in a dry...

Page 7: ...ent LRA is equal to or less than the nominal current FLA 4 3 Connecting the cables The device has external leads First connect the PE protective earth Connect the cables according to your application...

Page 8: ...ve earth 1 GND blue GND connection for control interface 2 0 10V PWM yellow Control input 0 10 V or PWM electrically isolated 3 10 V max 1 1 mA red Voltage output 10 VDC 1 1 mA electrically isolated s...

Page 9: ...e g in cyclic operation on and off via power supply Disconnect the device from the power supply When disconnecting be sure to disconnect the ground connection last 5 INTEGRATED PROTECTIVE FEATURES The...

Page 10: ...rigorously implemented around the world on the basis of German standards Right from the development stage ecological design technical safety and health protection are fixed criteria The following sec...

Page 11: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 51019 5 9970 ENU Change 96553 Approved 2017 10 26 Page 11 11 ebm papst Mulfinge...

Reviews: