ebm-papst K3G200-BD64-04 Operating Instructions Manual Download Page 8

Operating instructions

K3G200-BD64-04

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

No.

Conn.

Designation

Color

Function/assignment

1

Un +48 VDC

red

Power supply 48 VDC, maximum ripple 3.5%

2

0-10 VDC

yellow

Control input Re > 100 K

3

Tach

white

Tach output, 3 pulses per revolution, Isink max = 10 mA

4

GND

blue

Reference ground

Item no. 53019-5-9970 · ENU · Change 237649 · Approved 2021-09-13 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for K3G200-BD64-04

Page 1: ...thorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards a...

Page 2: ...tact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and...

Page 3: ...hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan...

Page 4: ...ing All dimensions in mm 1 Cable PVC AWG16 4x crimped ferrules 2 Direction of air flow V 3 Mounting dimensions Item no 53019 5 9970 ENU Change 237649 Approved 2021 09 13 Page 4 11 ebm papst Mulfingen...

Page 5: ...umber of blades 7 Direction of rotation Clockwise viewed toward rotor Degree of protection IP44 installation and position dependent Insulation class B Moisture F Environmental H protection class H1 In...

Page 6: ...the connection should be isolated from vibration e g using compensators or similar elements Ensure stress free attachment of the fan to the substructure The fan may not be handled in the area around...

Page 7: ...0 13 mm Operate the device with a safely isolated power supply Protective earth contact resistance according to EN 60335 Compliance with the resistance specifications according to EN 60335 for the pr...

Page 8: ...red Power supply 48 VDC maximum ripple 3 5 2 0 10 VDC yellow Control input Re 100 K 3 Tach white Tach output 3 pulses per revolution Isink max 10 mA 4 GND blue Reference ground Item no 53019 5 9970 E...

Page 9: ...witch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on yo...

Page 10: ...device 5 3 Disposal For ebm papst environmental protection and resource preservation are top priority corporate goals ebm papst operates an environmental management system which is certified in accor...

Page 11: ...ploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 53019 5 9970 ENU Change 237649 Approved 2021 09 13 Page 11 11 ebm papst Mulfinge...