3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable PVC AWG22, 4x crimped splices

2

Cable PVC AWG20, 3x crimped splices

3

Mounting dimensions

Item no. 53485-5-9970 · ENU · Change 82464 · Approved 2014-08-20 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for K3G175-RD53-03

Page 1: ...otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrica...

Page 2: ...he user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device R...

Page 3: ...ve devices Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e...

Page 4: ...All dimensions in mm 1 Cable PVC AWG22 4x crimped splices 2 Cable PVC AWG20 3x crimped splices 3 Mounting dimensions Item no 53485 5 9970 ENU Change 82464 Approved 2014 08 20 Page 4 11 ebm papst Mulfi...

Page 5: ...impeller combination in a standardized measurement setup 3 4 Technical description Weight 1 5 kg Fan size 175 mm Rotor surface Thick film passivated Impeller material PA plastic Housing material PA p...

Page 6: ...s at the customer end of the cable can damage the device Make sure the end of the cable is connected in a dry environment Only connect the device to circuits that can be switched off with an all pole...

Page 7: ...urrent FLA 4 3 Connecting the cables The device has external leads First connect the PE protective earth Connect the cables according to your application When doing so observe Chapter 4 4 Connection d...

Page 8: ...ive earth 1 GND blue GND connection for control interface 2 0 10V PWM yellow Control input 0 10 V or PWM electrically isolated 3 10V max 1 1mA red Voltage output 10 V 1 1 mA electrically isolated not...

Page 9: ...described in the table Fault Safety feature description function Rotor position detection error An automatic restart follows Blocked rotor After the blockage is removed the motor restarts automatical...

Page 10: ...d on the basis of German standards Right from the development stage ecological design technical safety and health protection are fixed criteria The following section contains recommendations for ecolo...

Page 11: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 53485 5 9970 ENU Change 82464 Approved 2014 08 20 Page 11 11 ebm papst Mulfinge...

Reviews: