ebm-papst K3G097-AK34-43 Operating Instructions Manual Download Page 4

Operating instructions

K3G097-AK34-43

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

6-pole header TE Junior Power Timer WE_9901118

1.1

+ UB

1.2

GND

1.3

PWM/LIN

1.4

INVLIN

1.5

ABSENK

1.6

Diagnostic output
Accessory part: Cable (460 mm) with mating connector, part no. 02001-4-1021 not included in scope of delivery
6-pole mating connector TE 929504-2, 4x plug contact TE 927771-1, 2x plug contact TE 927768-1

Item no. 50627-5-9970 · ENU · Change 225873 · Approved 2021-01-19 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for K3G097-AK34-43

Page 1: ...ly authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety haza...

Page 2: ...RNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device Injuries can result Do not wear any loose fitting or dangling clo...

Page 3: ...hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan...

Page 4: ...ABSENK 1 6 Diagnostic output Accessory part Cable 460 mm with mating connector part no 02001 4 1021 not included in scope of delivery 6 pole mating connector TE 929504 2 4x plug contact TE 927771 1 2...

Page 5: ...Number of blades 34 Balancing grade according to DIN ISO 21940 11 G 2 5 Direction of rotation Clockwise viewed toward rotor Degree of protection Motor IP24 KM Insulation class B Moisture F Environmen...

Page 6: ...damage to the device If the device slips during installation serious damage can result Ensure that the device is securely positioned at its place of installation until all fastening screws have been...

Page 7: ...GND Power supply GND reference ground 1 3 PWM LIN Analog voltage control input 0 10 V or PWM 1 4 INVLIN Control input inverse linear 1 5 ABSENK Lowering input 1 6 DIAG Diagnostic output Item no 50627...

Page 8: ...enance Switch off the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTIONS PO...

Page 9: ...ate goals ebm papst operates an environmental management system which is certified in accordance with ISO 14001 and rigorously implemented around the world on the basis of German standards Right from...

Page 10: ...ploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 50627 5 9970 ENU Change 225873 Approved 2021 01 19 Page 10 10 ebm papst Mulfinge...