background image

Operating instructions

K1G220-AA67-02

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

No.

Conn.

Designation

Color

Function/assignment

1

1

Un +48 VDC

red

Power supply 48 VDC, maximum ripple 3.5%

1

2

0-10 VDC

yellow

Control input Re > 100k

1

3

Tach

white

Tach output, 3 pulses per revolution, Isink max = 10 mA

1

4

GND

blue

Reference ground

Item no. 52665-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 7 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for K1G220-AA67-02

Page 1: ...thorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic s...

Page 2: ...y parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rota...

Page 3: ...mproper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant...

Page 4: ...awing All dimensions in mm 1 Cable PVC AWG20 4x crimped splice 2 Direction of air flow V 3 Mounting dimensions Item no 52665 5 9970 ENU Change 89188 Approved 2016 04 18 Page 4 9 ebm papst Mulfingen Gm...

Page 5: ...rotection Information on surface quality The surfaces of the products conform to the generally applicable industrial standard The surface quality may change during the production period This has no ef...

Page 6: ...ening 4 2 Electrical connection CAUTION Voltage The fan is a built in component and has no disconnecting switch Only connect the fan to circuits that can be switched off with an all pole disconnection...

Page 7: ...red Power supply 48 VDC maximum ripple 3 5 1 2 0 10 VDC yellow Control input Re 100k 1 3 Tach white Tach output 3 pulses per revolution Isink max 10 mA 1 4 GND blue Reference ground Item no 52665 5 9...

Page 8: ...switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on y...

Page 9: ...pecific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassembl...

Reviews: