3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable PVC 3G 0.5 mm²
3x splice

2

Cable PVC 3x 0.25 mm²
3x splice

3

Tapping hole prepared for self-tapping screw for fastening plastics (Remform) dia. 4 mm, clearance for screw max. 15 mm, torque is to be
determined on the basis of the screw.

4

5x sheet metal nut for thread EN ISO 1478-ST4.8 (max. screw length 16 mm plus thickness of mounting material)

5

Screw-on domes are only permissible for Flowgrid!

6

Connecting sleeve not suitable for installation with pipe clamps

Item no. 56519-5-9970 · ENU · Change 200888 · Approved 2021-11-19 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for G3G190-RG19-05

Page 1: ...authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basi...

Page 2: ...y that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accide...

Page 3: ...prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration...

Page 4: ...or screw max 15 mm torque is to be determined on the basis of the screw 4 5x sheet metal nut for thread EN ISO 1478 ST4 8 max screw length 16 mm plus thickness of mounting material 5 Screw on domes ar...

Page 5: ...ccordance with its degree of protection Information on surface quality The surfaces of the products conform to the generally applicable industrial standard The surface quality may change during the pr...

Page 6: ...to circuits that can be switched off with an all pole disconnection switch When working on the device secure the system machine in which the device is installed so as to prevent it from being switched...

Page 7: ...r can lead to the residual current devices tripping instantly We recommend the use of residual current circuit breakers RCCB with a trip threshold of 300 mA and delayed tripping super resistant charac...

Page 8: ...see nameplate for voltage range 1 PE green yellow Protective earth 7 PWM yellow Control input PWM Isink 5 10 mA SELV adjustable curve 5 Tacho white Tach output open collector 1 pulse per revolution S...

Page 9: ...e g in cyclic operation on and off via power supply Disconnect the device from the power supply When disconnecting be sure to disconnect the ground connection last 5 INTEGRATED PROTECTIVE FEATURES Th...

Page 10: ...necessary after that period contact ebm papst Adapt the maintenance intervals to the actual level of dust exposure 6 2 Safety inspection NOTE High voltage test The integrated EMC filter has Y capacito...

Page 11: ...lating materials Cables and wires Electronic scrap e g circuit boards Only ferrite magnets and not rare earth magnets are used in external rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magn...

Reviews: