background image

Operating instructions

G3G146-FK07-02

Translation of the original operating instructions

4.4 Connection screen

Line

No.

Signal

Colour

Function / assignment

CON10 L

black

Power supply 230 VAC, 50-60 Hz, see type plate for voltage range

CON11 N

blue

Neutral conductor

CON12 PE

green/
yellow

Protective earth

1

GND

blue

GND - Connection for control interface

2

0- 10V PWM

yellow

Control input 0 - 10 V or PWM, electrically isolated

3

10V/ max 1.1mA

red

Voltage output 10V/ 1.1mA, electrically isolated, not short-circuit-proof.

4

Tach

white

Tach output: open collector, 1 pulse per revolution, electrically isolated

Item no. 51765-5-9970 · Revision 77287 · Release 2012-04-04 · Page 7 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for G3G146-FK07-02

Page 1: ...sed specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards s...

Page 2: ...ire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Befo...

Page 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Page 4: ...have the unit mm 1 Connection line PVC 4X AWG22 4x brass lead tips crimped 2 Connection line PVC 3X AWG20 3x brass lead tips crimped Item no 51765 5 9970 Revision 77287 Release 2012 04 04 Page 4 10 eb...

Page 5: ...holes None open rotor Operation mode S1 Motor bearing Ball bearing Technical features Output 10 VDC max 1 1 mA Tach output Motor current limit Soft start Control input 0 10 VDC PWM Over temperature pr...

Page 6: ...isconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data Before connecting the device ensure that the supply voltage matches the operating voltag...

Page 7: ...1 GND blue GND Connection for control interface 2 0 10V PWM yellow Control input 0 10 V or PWM electrically isolated 3 10V max 1 1mA red Voltage output 10V 1 1mA electrically isolated not short circui...

Page 8: ...ion Switch on the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply Switching off the device for maintenance work Switch on the device via the co...

Page 9: ...ise correct connection see connection diagram Overtemperature of electronics motor Insufficient cooling Improve cooling Let the device cool down To reset the error message switch off the mains supply...

Page 10: ...eplace wires Check the ball bearings to ensure they are quiet can move easily and are free of play Manual check by turning the rotor in shut off state At least every 6 months Replace device in case of...