Operating instructions

G3G133-RF15-03

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable PVC AWG20
3x splice

2

Cable PVC AWG22
4x splice

3

Tapping hole prepared for dia. 4 mm self-tapping screw for fastening plastics, max. screw-in depth 9 mm

4

5x sheet metal nut for thread EN ISO 1478-ST4.8 (max. screw length 14 mm plus material thickness of mounting)

5

Screw-on domes are only permissible for Flowgrid!

6

Connecting sleeve not suitable for installation with pipe clamps

Item no. 56994-5-9970 · ENU · Change 274903 · Approved 2023-01-16 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for G3G133-RF15-03

Page 1: ...otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electric...

Page 2: ...ding measures have to be taken by the user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanica...

Page 3: ...prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration...

Page 4: ...plastics max screw in depth 9 mm 4 5x sheet metal nut for thread EN ISO 1478 ST4 8 max screw length 14 mm plus material thickness of mounting 5 Screw on domes are only permissible for Flowgrid 6 Conn...

Page 5: ...1 CE UKCA Use the device in accordance with its degree of protection Information on surface quality The surfaces of the products conform to the generally applicable industrial standard The surface qu...

Page 6: ...ons for voltage current insulation material capacity etc Route cables so that they cannot be touched by any rotating parts CAUTION Voltage The device is a built in component and has no disconnecting s...

Page 7: ...e frequency drives residual current devices cannot provide personal safety while the device is being operated When the device power supply is switched on pulsed charging currents from the capacitors i...

Page 8: ...ve earth 1 GND blue GND connection for control interface 2 0 10V PWM yellow Control input 0 10 V or PWM electrically isolated 3 10 V max 1 1 mA red Voltage output 10 VDC 1 1 mA electrically isolated s...

Page 9: ...trol input Do not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 INTEGRATED PROTECTIVE FEATURES The integrated protective functions...

Page 10: ...ctual level of dust exposure 6 2 Safety inspection NOTE High voltage test The integrated EMC filter has Y capacitors The tripping current is exceeded when AC testing voltage is applied Test the device...

Page 11: ...xternal rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magnets can be disposed of in the same way as normal iron and steel Electrical insulating materials on the product in cables and wires...

Reviews: