3.2 Nominal data
Motor
M3G074-BF
Phase
1~
Nominal voltage / VAC
230
Nominal voltage
range / VAC
208 .. 250
Frequency / Hz
50/60
Type of data definition
me
Speed / min
-1
13000
Power input / W
600
Current draw / A
2.6
Min. ambient temperature
/ °C
-25
Max. ambient
temperature
/ °C
50
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Technical features
Mass
4.0 kg
Size
125 mm
Surface of rotor
Coated in black
Material of impeller
Aluminium sheet
Number of blades
6
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"B"
Mounting position
Any
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Technical features
- Tach output
- Motor current limit
- PFC, active
- Soft start
- Control input 0-10 VDC / PWM
- Over-temperature protected
electronics / motor
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads
With plug
Motor protection
Locked-rotor protection
Product conforming
to standard
EN 61800-5-1; CE
Approval
VDE; UL 507; CSA C22.2 Nr.113
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
3.6 Electromagnetic compatibility
EMC interference
immunity
Acc. to EN 61000-6-2
EMC harmonics
Acc. to EN 61000-3-2/3
EMC interference
emission
Acc. to EN 61000-6-4 (industrial
environment)
Item no. 50979-5-9970 · Revision 81898 · Release 2014-02-12 · Page 5 / 10