ebm-papst G2D180-BD18-11 Operating Instructions Manual Download Page 4

Operating instructions

G2D180-BD18-11

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable silicone 4G 0.5 mm², 4x crimped splices

Item no. 11905-5-9970 · ENU · Change 99370 · Approved 2018-04-26 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for G2D180-BD18-11

Page 1: ...and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the elec...

Page 2: ...ndstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device Injuries can result Do not wear any loose fitting or da...

Page 3: ...the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This al...

Page 4: ...DATA 3 1 Product drawing All dimensions in mm 1 Cable silicone 4G 0 5 mm 4x crimped splices Item no 11905 5 9970 ENU Change 99370 Approved 2018 04 26 Page 4 11 ebm papst Mulfingen GmbH Co KG Bachm hle...

Page 5: ...parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Inform...

Page 6: ...witched off with an all pole disconnection switch 4 2 1 Requirements Check whether the information on the nameplate matches the connection data Before connecting the device make sure the power supply...

Page 7: ...4 3 1 Motor protection WARNING Device has no overheating protection The device is supplied without any automatic overheating protection The device can become hot and catch fire For the version without...

Page 8: ...tion direction by reversing two phases Three phase motor Y Star connection L1 black L2 blue L3 brown PE green yellow Item no 11905 5 9970 ENU Change 99370 Approved 2018 04 26 Page 8 11 ebm papst Mulfi...

Page 9: ...d connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and co...

Page 10: ...onmental protection and resource preservation are top priority corporate goals ebm papst operates an environmental management system which is certified in accordance with ISO 14001 and rigorously impl...

Page 11: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 11905 5 9970 ENU Change 99370 Approved 2018 04 26 Page 11 11 ebm papst Mulfinge...

Reviews: