ebm-papst G1G170-AB31-53 Operating Instructions Manual Download Page 4

Operating instructions

G1G170-AB31-53

Translation of the original operating instructions

In addition, all application options that are not listed
under proper use.

Item no.: 51290-5-9970 · Revision: 74201 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 4 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for G1G170-AB31-53

Page 1: ...ted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re...

Page 2: ...Escaping gas may also cause explosions Never open the blower WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be inju...

Page 3: ...ating instructions Using the device in accordance with the permitted ambient temperature see chapter 3 6 Transport and storage conditions and chapter Only using the device in stationary systems Instal...

Page 4: ...addition all application options that are not listed under proper use Item no 51290 5 9970 Revision 74201 Print out 2012 04 11 Y Uhlmann VM TDO Page 4 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 7...

Page 5: ...ard scope of delivery tyco No 350 766 1 female terminal tyco No 926 884 1 2 1 L 2 2 N 2 3 PE 3 5 pole strip mating connector not included in delivery Molex No 39 01 4050 female connector Molex No 39 0...

Page 6: ...ousing material Die cast aluminium Direction of rotation Clockwise seen on rotor Type of protection IP 20 Insulation class B Humidity class F2 1 Mounting position Any Condensate discharge holes None C...

Page 7: ...ectrical voltage The device is a built in component and features no electrically isolating switch Connect the device only to circuits that can be switched off using an all pole disconnecting switch Wh...

Page 8: ...sing an all pole disconnecting switch When working on the device you must switch off the system machine in which the device is installed and secure it from being switched on again Check the PIN assign...

Page 9: ...2 2 DUE Speed monitoring output connection monitoring circuit output 3 pulses per revolution current source 2 mA ST2 3 N C Not assigned ST2 4 PWM PWM 2 6 kHz control input PWM on n 100 PWM low n 0 ST2...

Page 10: ...supply Start the device by changing the input signal 4 7 Switching off the device Switching off the device during operation Switch on the device via the control input Do not switch the motor e g in c...

Page 11: ...ean the device if imbalance is still evident after cleaning replace the device If you have attached any weight clips during cleaning make sure to remove them afterwards Motor does not turn Mechanical...

Page 12: ...n Mounting of protective earth connection Visual inspection At least every 6 months Fasten Check the insulation of the wires for damage Visual inspection At least every 6 months Replace wires Check th...

Reviews: