You can control the blower either via the 0-10 VDC input or the
PWM input. Note: Inputs cannot be used simultaneously.

3.2 Nominal data

Motor

M1G055-BD

Phase

1~

Nominal voltage / VAC

230

Frequency / Hz

50

Type of data definition

ml

Speed / min

-1

5400

Power input / W

94

Current draw / A

0.67

Min. ambient temperature
/ °C

-25

Max. ambient temperature
/ °C

50

Min. temp. of flow
medium / °C

-25

Max. temp. of flow
medium / °C

+80

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

1.6 kg

Size

144 mm

Surface of rotor

Thick layer passivated

Material of protective
cover

PP plastic

Material of impeller

PA plastic

Housing material

Die-cast aluminium

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 20

Insulation class

"B"

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Premix

Not suitable for pre-mixture.

Motor bearing

Ball bearing

Technical features

- Tach output
- Motor current limit
- Control input PWM

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Motor protection

Reverse polarity and locked-rotor
protection

Remark

Complete unit must be tested for required
approvals.

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 51289-5-9970 · Revision 79946 · Release 2013-12-02 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for G1G144-AF25-01

Page 1: ...authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards...

Page 2: ...rically live parts Escaping gas may also cause explosions Never open the blower WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the devic...

Page 3: ...ems Installing the device into an overall system for moving air Commissioning the built in component only after installation in the customer unit Operating the device with all protective features in p...

Page 4: ...1 female terminal tyco No 926 884 1 2 1 L 2 2 N 2 3 PE 3 5 pole strip mating connector not included in delivery Molex No 39 01 4050 female connector Molex No 39 00 0059 3 1 3 2 Speed monitoring 3 3 No...

Page 5: ...le for pre mixture Motor bearing Ball bearing Technical features Tach output Motor current limit Control input PWM Touch current acc IEC 60990 measuring network Fig 4 TN system 3 5 mA Motor protection...

Page 6: ...inst accidental contact is provided Before working on the electrical connection the connections to the mains supply and PE must be shorted CAUTION Electrical voltage The device is a built in component...

Page 7: ...n be switched off using an all pole disconnecting switch When working on the device you must switch off the system machine in which the device is installed and secure it from being switched on again C...

Page 8: ...iginal operating instructions 4 4 Connection screen Item no 51289 5 9970 Revision 79946 Release 2013 12 02 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 F...

Page 9: ...y 0 PWM to the PWM control input if you are using the PWM control input Apply the nominal voltage to the voltage supply Start the device by changing the input signal 4 7 Switching off the device Switc...

Page 10: ...if imbalance is still evident after cleaning replace the device If you have attached any weight clips during cleaning make sure to remove them afterwards Motor does not turn Mechanical blockage Switc...

Page 11: ...l inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection At least every 6 months Fasten Check the insulation of the wires for damage Visual inspection At l...

Reviews: