3.2 Nominal data

Motor

M1G055-CF

Phase

1~

Nominal voltage / VAC

230

Frequency / Hz

50/60

Speed / min

-1

1650

Power input / W

43

Current draw / A

0.48

Min. ambient
temperature
/ °C

-25

Max. ambient
temperature
/ °C

60

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

2.3 kg

Size

140 mm

Surface of rotor

Coated in black

Material of impeller

PP plastic

Housing material

Die-cast aluminium

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 20

Insulation class

"B"

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Technical features

- Day/Night/Party selection
- Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Motor protection

Locked-rotor protection

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1

Approval

VDE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

3.6 Electromagnetic compatibility

EMC interference
immunity

Acc. to EN 61000-6-2

EMC harmonics

Acc. to EN 61000-3-2/3

EMC interference
emission

Acc. to EN 61000-6-3 (household
environment)

Item no. 50989-5-9970 · Revision 72138 · Release 2014-01-24 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

E-mail: [email protected]  

Summary of Contents for G1G140-AW31-42

Page 1: ...chnical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules...

Page 2: ...come into contact with the rotor and impeller can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING R...

Page 3: ...ructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Moving air that contains abrasive particles Moving highly corrosive air e g salt spray mis...

Page 4: ...3 TECHNICAL DATA 3 1 Product drawing All measures have the unit mm 1 Shown without cover Item no 50989 5 9970 Revision 72138 Release 2014 01 24 Page 4 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D...

Page 5: ...Variable Protection class I if protective earth is connected by customer Product conforming to standard EN 60335 1 Approval VDE For cyclic speed loads note that the rotating parts of the device are d...

Page 6: ...e end on the customers side and can damage the device Make sure that the cable end is connected in a dry environment Connect the device only to circuits that can be switched off using an all pole disc...

Page 7: ...e original operating instructions 4 3 Connection screen Item no 50989 5 9970 Revision 72138 Release 2014 01 24 Page 7 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938 81...

Page 8: ...Apply the nominal voltage to the voltage supply Start the device by changing the input signal 4 6 Switching off the device Switching off the device during operation Switch off the device via the contr...

Page 9: ...nergise correct connection see connection diagram Overtemperature of electronics motor Insufficient cooling Improve cooling Let the device cool down To reset the error message switch off the mains sup...

Page 10: ...the insulation of the wires for damage Visual inspection At least every 6 months Replace wires Item no 50989 5 9970 Revision 72138 Release 2014 01 24 Page 10 10 ebm papst Mulfingen GmbH Co KG Bachm hl...