ebm-papst D4D225-CC01-02 Operating Instructions Manual Download Page 8

Operating instructions

D4D225-CC01-02

Translation of the original operating instructions

4.4 Connection screen

Three-phase motor

Y

Star connection

Δ

Delta connection

L1

black

L2

black

L3

black

V2

black

U2

black

W2

black

PE

green / yellow

Item no. 10889-5-9970 · ENG · Revision 89188 · Release 2016-06-13 · Page 8 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for D4D225-CC01-02

Page 1: ...thorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards s...

Page 2: ...chanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Before working on the system machine...

Page 3: ...ing instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Resona...

Page 4: ...Product drawing All measures have the unit mm 1 Connection line AWG20 7x brass lead tips crimped Item no 10889 5 9970 ENG Revision 89188 Release 2016 06 13 Page 4 10 ebm papst Mulfingen GmbH Co KG Ba...

Page 5: ...surement category are detailed in the CE declaration Specific ratio 1 pf 100 000 Pa Data definition with optimum efficiency The ErP data is determined using a motor impeller combination in a standardi...

Page 6: ...ovided Before working on the electrical connection the connections to the mains supply and PE must be shorted CAUTION Electrical voltage The device is a built in component and features no electrically...

Page 7: ...ction screen 4 3 1 Motor protection WARNING Device without overheating protection The device is delivered without any automatically functioning overheating protection The device can become hot and bur...

Page 8: ...motor Y Star connection Delta connection L1 black L2 black L3 black V2 black U2 black W2 black PE green yellow Item no 10889 5 9970 ENG Revision 89188 Release 2016 06 13 Page 8 10 ebm papst Mulfingen...

Page 9: ...the supply line When disconnecting be sure to disconnect the earth wire connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return the dev...

Page 10: ...specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassem...