ebm-papst D3G146-LU03-01 Operating Instructions Manual Download Page 8

Operating instructions

D3G146-LU03-01

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

No.

Conn.

Designation

Color

Function/assignment

CON10

10.1

PE

green/
yellow

Protective earth

CON10

10.2

L

black

Power supply 230 VAC, 50-60 Hz, see nameplate for voltage range

CON10

10.3

N

blue

Neutral conductor

CON11

11.1

10 V/max. 1.1
mA

red

Voltage output 10 V, 1.1 mA, electrically isolated, not short-circuit-proof

CON11

11.2

Tach

white

Tach output: Open collector, 1 pulse per revolution, electrically isolated, Isink max = 10 mA

CON11

11.3

0-10 V PWM

yellow

Control input 0-10 V or PWM, electrically isolated

CON11

11.4

GND

blue

GND connection for control interface

Item no. 51143-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for D3G146-LU03-01

Page 1: ...alled operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to...

Page 2: ...he user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device R...

Page 3: ...ve devices Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e...

Page 4: ...ch 1 3 0 10V lin PWM 1 4 GND 2 Connector Lumberg 3642 03 K01 pluggable with 3626 03 K01 2 1 PE 2 2 L 2 3 N 3 4x sheet metal nut for thread EN ISO 1478 ST4 8 min screw length 14 5 mm plus material thic...

Page 5: ...current according to IEC 60990 measuring circuit Fig 4 TN system 3 5 mA Electrical hookup With plug Motor protection Thermal overload protector TOP internally connected with cable Variable Protection...

Page 6: ...r the data on the nameplate match the connection data Before connecting the device make sure the power supply matches the device voltage Only use cables designed for the current level indicated on the...

Page 7: ...ector s pin assignment Connect the built in connector with the mating connector Ensure that the connector is properly engaged Item no 51143 5 9970 ENU Change 89188 Approved 2016 04 18 Page 7 11 ebm pa...

Page 8: ...10 V max 1 1 mA red Voltage output 10 V 1 1 mA electrically isolated not short circuit proof CON11 11 2 Tach white Tach output Open collector 1 pulse per revolution electrically isolated Isink max 10...

Page 9: ...in the event of the faults described in the table Fault Safety feature description function Rotor position detection error An automatic restart follows Blocked rotor After the blockage is removed the...

Page 10: ...ge ecological design technical safety and health protection are fixed criteria The following section contains recommendations for ecological disposal of the product and its components 6 2 1 Country sp...

Page 11: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 51143 5 9970 ENU Change 89188 Approved 2016 04 18 Page 11 11 ebm papst Mulfinge...