Operating instructions
D2E146-CD51-23
Translation of the original operating instructions
3.2 Nominal data
Motor
M2E068-DF
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
ml
ml
Valid for approval /
standard
CE
CE
Speed / min
-1
1850
2100
Power input / W
230
250
Current draw / A
1.01
1.09
Motor capacitor / µF
4
4
Capacitor voltage / VDB
450
450
Capacitor standard
P2 (CE)
P2 (CE)
Min. back pressure / Pa
200
300
Max. ambient
temperature / °C
50
50
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
26.3
26.1
33.1
Efficiency grade N
37.2
37
44
Power input P
e
/ kW
0.19
Air flow q
v
/ m³/h
520
Pressure increase total p
sf
/ Pa
350
Speed n / min
-1
2270
Data established at point of optimum efficiency
3.4 Technical features
Mass
3.9 kg
Size
146 mm
Surface of rotor
Uncoated
Material of impeller
Sheet steel, sendzimir galvanised
Housing material
Sheet steel, hot-dip galvanised
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 44
Insulation class
"F"
Humidity class
F0
Mounting position
Any
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Axial
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 10583-5-9970 · Revision 68158 · Release 2009-08-17 · Page 5 / 9