ebm-papst CGCXX00000 Operating And Maintenance Instructions Manual Download Page 3

Operating and Maintenance Instructions 

210-OMI14028-Iss1 

ORIGINAL INSTRUCTIONS 

Page 3 of 6 

 

 

ebm-papst UK Ltd 

 

Chelmsford Business Park  Chelmsford  Essex  CM2 5EZ

  

Telephone: +44(0)1245468555  Fax: +44(0)1245466336  
e-mail 

[email protected]

  

 

                                                                                                                                                                                      

 

 

Introduction 

The Configurable Generic Controller (CGC) is designed to regulate the rotational speed of ebm-papst 0-10V and 

open collector PWM controlled fans. It operates on a wide supply voltage range from 10 to 57 volts DC, and due 
to its low power consumption, it can be powered from the ebm-papst small EC motors 10V DC output. 
The controller’s factory default has no profile assigned to it. A configuration file must be created and downloaded 

to the controller in order for it to produce an output signal in response to an input signal. 
Please  see 

www.ebmpapst.co.uk/cgc

  for  a  list  of  configuration  files  provided  by  ebm-papst,  which  have  been 

derived from legacy CPC and EC controllers and must be used as their direct replacement. 

 

Specification 

 
Part Number 

CGCXX00000 

Supply Voltage 

10V or 12 to 57V DC 

Supply Current 

Up to 1 mA (@10VDC), 4mA (@57V) 

Control Output 

Programmable 0-10V DC at 2Khz (Control) or 
Open collector PWM fan speed control signal at 8Khz (Control) 

Open Collector Alarm Output max sink 60Vdc – 100mA (Monitor) 

Control Inputs 

Programmable Temperature or 0-10V (Control) 

Open Collector Fan Tachometer (Monitor) 

Maximum Number of Fans 

16 x EC Fans (10V – 1mA supply)    

400 x EC Fans (12-48Vdc)    

400 x DC Fans (12-48Vdc) 

Operating Temperature 

-30°C to +60°C 

 
Installation 

The CGC is designed as a component part to be installed in a clean and dry area within the user’s equipment or 

an enclosure to prevent access whilst operating or ingress of dust and moisture. There are 4 x Ø 3.5mm PCB 

fixing holes available for installing the board to its enclosure or fixture. It is recommended that the control signal 

cable  is  kept  separate  from  mains  supply  wiring.  Shielded  cabling  may  be  used  if  appropriate  to  prevent 
unwanted interference. 

 

Accessories 
Thermistor lead  

SN1060 (included with the controller) 

Programming lead 

210-HAR11887 

Alarm lead 

210-HAR10579 (included with the controller) 

Summary of Contents for CGCXX00000

Page 1: ...ail sales uk ebmpapst com Table of Contents Safety Notice 2 Introduction 3 Specification 3 Installation 3 Mechanical Outline Connection Detail 4 Connections 5 Function 5 Alarms 5 Monitor 6 Transport and Storage 6 Maintenance and Servicing 6 CE Document Copy of first sheet 6 Part No CGCXX00000 Description Configurable Generic Controller Issue Date Bug no Comments 1 29 09 2017 First Release Felipe P...

Page 2: ...tructions carefully before installation and commissioning of the control device Safety Notice CAUTION Safety The configurable generic controller is only suitable for a low voltage 10V or 12 to 57V DC supply Electrical installations should only be carried out by qualified personnel CAUTION Electro Static Discharge Many modern electronic components are susceptible to damage from Electro Static Disch...

Page 3: ...ect replacement Specification Part Number CGCXX00000 Supply Voltage 10V or 12 to 57V DC Supply Current Up to 1 mA 10VDC 4mA 57V Control Output Programmable 0 10V DC at 2Khz Control or Open collector PWM fan speed control signal at 8Khz Control Open Collector Alarm Output max sink 60Vdc 100mA Monitor Control Inputs Programmable Temperature or 0 10V Control Open Collector Fan Tachometer Monitor Maxi...

Page 4: ...ions 210 OMI14028 Iss1 ORIGINAL INSTRUCTIONS Page 4 of 6 ebm papst UK Ltd Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone 44 0 1245468555 Fax 44 0 1245466336 e mail sales uk ebmpapst com Mechanical Outline Connection Detail ...

Page 5: ...y ebm papst provides a set of pre made configuration files available at www ebmpapst co uk cgc The pre made configuration files are derived from legacy CPC and EC controllers and must be used as their direct replacement For details on how to use the GUI to re configure a controller please refer to operational manual 210 OMI14048 available from www ebmpapst co uk cgc Alarms The alarm output is an o...

Page 6: ...ts graphical user interface The routine monitors real time the controller s input and output and projects the results on the profile plot For more information please see operation manual 210 OMI14048 available at www ebmpapst co uk cgc Transport and Storage PCBs should be transported in anti static build up bag or static dissipative bags Store in a dry environment Storage temperature 30 C to 70 C ...

Page 7: ... AN08 02 A4E330 AP18 13 R1G225 AG15 11 R2D270 AB12 09 R2E220 AB08 12 R3G310 AL09 30 R4E400 AP15 10 REF100 11 14 RG90 18 14N 9496 2 4039 1 95779 1 5171 A2D240 AA02 10 A2D250 AA06 52 A2E300 AP02 01 A4E300 AS72 01 G2E120 FV56 16 G2E160 AY47 57 QR06A 2 106349 R1G250 AQ21 52 R1G250 AQ37 52 R2E180CH0312 R2E225 BD92 36 R3G175 AF25 02 LZ27 REF100 11 12 RG125 19 12N 2 RH31M 6 104372 RH56M 6 204689 RLF100 1...

Reviews: