3. TECHNICAL DATA

3.1 Graphic rendition of products

All measures have the unit mm.

1

Direction of air flow "A"

2

Connection line PVC, 4x brass lead tips crimped

3

Depth of screw max. 5 mm

Item no.: 10743-5-9970 · Revision: --- · Print-out: 2012-02-16 · Y. Uhlmann (VM-TDO) · Page 4 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for A4E300-AP26-70

Page 1: ...ystem Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic saf...

Page 2: ...ome entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNING Depend...

Page 3: ...following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highly co...

Page 4: ...measures have the unit mm 1 Direction of air flow A 2 Connection line PVC 4x brass lead tips crimped 3 Depth of screw max 5 mm Item no 10743 5 9970 Revision Print out 2012 02 16 Y Uhlmann VM TDO Page...

Page 5: ...harge holes Rotor side Operation mode S1 Motor bearing Ball bearing Leakage current 0 75 mA Motor protection Thermal overload protector TOP wired internally Cable exit Variable Protection class I if p...

Page 6: ...ed in a dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the...

Page 7: ...ions 4 4 Connection diagram U1 blue Z brown U2 black PE green yellow Item no 10743 5 9970 Revision Print out 2012 02 16 Y Uhlmann VM TDO Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mul...

Page 8: ...lectric shock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger of injury...

Page 9: ...device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of p...