background image

Operating instructions

A4D400-AP12-02

Translation of the original operating instructions

3.2 Nominal data

Motor

M4D074-EI

Phase

3~

3~

3~

3~

Nominal voltage / VAC

230

230

400

400

Connection

Δ

Δ

Y

Y

Frequency / Hz

50

60

50

60

Type of data definition

fa

fa

fa

fa

Valid for approval /
standard

CE

CE

CE

CE

Speed (rpm) / min

-1

1450

1690

1450

1690

Power input / W

135

185

135

185

Current draw / A

0.76

0.68

0.44

0.39

Max. back pressure / Pa

105

120

105

120

Min. ambient
temperature / °C

-25

-25

-25

-25

Max. ambient
temperature / °C

40

40

40

40

Starting current / A

3.0

3.0

1.7

1.7

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data in accordance with ecodesign regulation EU 327/
2011

Actual

Request 2015

01 Overall efficiency η

es

/ %

34.4

29.3

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

45.1

40

05 Variable speed drive

No

06 Year of manufacture

The year of manufacture is specified on the
rating plate on the product.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
County court Stuttgart · HRA 590344
D-74673 Mulfingen

08 Type

A4D400-AP12-02

09 Power input P

e

/ kW

0.2

09 Air flow q

v

/ m³/h

2805

09 Pressure increase total p

sf

/

Pa

92

10 Speed (rpm) n / min

-1

1390

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data definition with optimum efficiency. The ErP data is determined using a motor-impeller

combination in a standardised measurement configuration.

3.4 Technical features

Mass

4.2 kg

Size

400 mm

Motor size

74

Surface of rotor

Coated in black

Material of blades

Sheet steel, coated in black

Number of blades

5

Direction of air flow

A

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP44; Depending on installation and
position as per EN 60034-5

Insulation class

"B"

Humidity (F) /
environmental
protection class (H)

H1

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensation
drainage holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

EAC; CCC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

;

Use the device in accordance with its protection type.

Notes on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may vary during the production period.
Strength, dimensional stability and dimensional accuracy are not affected
by this.
The colour pigments of the paints used react perceptibly to UV light over
the course of time. This does not however have any influence on the
technical properties of the products. To prevent the formation of patches
and fading, the product is to be protected against UV radiation. Changes
in colour are not a reason for complaint and are not covered by the
warranty.

3.5 Mounting data

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

For depth of screw, see chapter 3.1 Product drawing

Strength class for
mounting screws

8.8

Any further mounting data required can be taken from the product
drawing or Section chapter 4.1 Connecting the mechanical system.

Item no. 11312-5-9970 · ENG · Revision 205161 · Release 2019-11-14 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for A4D400-AP12-02

Page 1: ...horised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards st...

Page 2: ...movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Before working on the system machine wait unti...

Page 3: ...d and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted fr...

Page 4: ...have the unit mm 1 Connection line PVC 7G 0 5mm 7x brass lead tips crimped 2 Direction of air flow A 3 Depth of screw max 10 mm Item no 11312 5 9970 ENG Revision 205161 Release 2019 11 14 Page 4 11 eb...

Page 5: ...Coated in black Material of blades Sheet steel coated in black Number of blades 5 Direction of air flow A Direction of rotation Clockwise seen on rotor Type of protection IP44 Depending on installatio...

Page 6: ...y and PE must be shorted CAUTION Electrical voltage The fan is a built in component and features no electrically isolating switch Only connect the fan to circuits that can be switched off with an all...

Page 7: ...ency converter must be checked by the customer following installation in the end device 4 3 Connection of the cables External leads are brought out of device First connect the PE protective earth conn...

Page 8: ...ersing two phases Three phase motor Delta connection Y Star connection L1 U1 black L2 V1 blue L3 W1 brown U2 green V2 white W2 yellow Item no 11312 5 9970 ENG Revision 205161 Release 2019 11 14 Page 8...

Page 9: ...e supply line When disconnecting be sure to disconnect the earth wire connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return the devic...

Page 10: ...hs Repair or replacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspec...

Page 11: ...external rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magnets can be disposed of in the same way as normal iron and steel Electrical insulating materials on the product in cables and wires...

Page 12: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information ebm papst A4D400 AP12 02...

Reviews: