ebm-papst A2D300-AP02-01 Operating Instructions Manual Download Page 2

Operating instructions

A2D300-AP02-01

Translation of the original operating instructions

CAUTION
In the event of failure, there is electric voltage at the
rotor and impeller

The rotor and impeller are base insulated.
→ Do not touch the rotor and impeller once they are installed.

CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.

Danger of injury
→ Keep out of the danger zone of the device.
→ When working on the device, switch off the mains

supply voltage and secure the latter from being switched on
again.

→ Wait until the device stops.

1.5 Safety and protective functions

DANGER
Missing safety device and non-functioning safety device

If there is no safety device, you could be seriously injured, for
example if you reach into the running device or your hands are
sucked into it.
→ Operate the device only with a fixed and isolating safety

protection and a fixed guard grille.
The guard must withstand the kinetic energy of a fan blade
detaching at maximum speed.

→ The device is a built-in component. You, the owner/

operator, are responsible for providing adequate protection for
the device.

→ Shut down the device immediately if you detect a

missing or ineffective protective feature.

1.6 Electromagnetic radiation

Interference from electromagnetic radiation is possible, e.g. in conjunction
with open and closed-loop control devices.
If unacceptable emission intensities occur when the fan is installed,
appropriate shielding measures have to be taken by the user.

NOTE
Electrical or electromagnetic interferences after
integrating the device in installations on the customer's
side.

→ Verify that the entire setup is EMC compliant.

1.7 Mechanical movement

DANGER
Rotating device

Body parts that come into contact with the rotor and impeller
can be injured.
→ Secure the device against accidental contact.
→ Before working on the system/machine, wait until all

parts have come to a standstill.

WARNING
Rotating device

Long hair, loose items of clothing and jewellery could become
entangled and pulled into the device. You could be injured.
→ Do not wear any loose clothing or jewellery while working

on rotating parts.

→ Protect long hair by wearing a cap.

1.8 Emission

WARNING
Depending on the installation and operating conditions,
a sound pressure level greater than 70 dB(A) may arise.

Danger of noise-induced hearing loss
→ Take appropriate technical safety measures.
→ Protect operating personnel with appropriate safety

equipment, e.g. hearing protection.

→ Also observe the requirements of local agencies.

1.9 Hot surface

CAUTION
High temperature at the motor housing

Danger of burn injuries
→ Ensure that sufficient protection against accidental contact is

provided.

1.10 Transport

NOTE
Transport of device

→ Transport the device in its original packaging only.
→ Secure the device so that it does not slip, e.g. by using a

clamping strap.

1.11 Storage

;

Store the device, partially or fully assembled, in a dry and
weatherproof manner in the original packing in a clean environment.

;

Protect the device from environmental impacts and dirt until the final
installation.

;

We recommend storing the device for a maximum up to one year to
guarantee proper operation and longest possible service life.

;

Even devices explicitly suited for outdoor use are to be stored as
described prior to being commissioned.

;

Maintain the storage temperature, see
chapter 3.6 Transport and storage conditions.

1.12 Disposal

When disposing of the device, please comply with all relevant
requirements and regulations applicable in your country.

Item no. 10364-5-9970 · Revision 82795 · Release 2014-05-08 · Page 2 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for A2D300-AP02-01

Page 1: ...al staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any...

Page 2: ...nd impeller can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair loose item...

Page 3: ...tions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that c...

Page 4: ...ve the unit mm 1 Direction of air flow V 2 Depth of screw max 10 mm 3 Connection line PFA AWG20 green yellow AWG18 7x lead tips crimped Item no 10364 5 9970 Revision 82795 Release 2014 05 08 Page 4 9...

Page 5: ...Direction of air flow V Direction of rotation Counter clockwise seen on rotor Type of protection IP 44 Depending on installation and position as per EN 60034 5 Insulation class F Humidity class F1 2 M...

Page 6: ...fore connecting the device ensure that the supply voltage matches the operating voltage of the device Only use cables designed for current according to the type plate For determining the cross section...

Page 7: ...ar connection Delta connection L1 U1 black U2 green L2 V1 blue V2 white L3 W1 brown W2 yellow PE green yellow Item no 10364 5 9970 Revision 82795 Release 2014 05 08 Page 7 9 ebm papst Mulfingen GmbH C...

Page 8: ...ltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device CAUTION The motor restarts automatically when operating...

Page 9: ...replacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least...

Reviews: