background image

page 3 of 5 

 

An in situ assessment must be conducted of the heating behavior 
(appropriate and inappropriate operation), the protection against 
contact, electrical shocks, impact of foreign objects or water and the 
usage at altitudes higher than 2000 meters. 
 
Contact ebm-papst if you have specific queries regarding the product. 

TECHNICAL DATA

 

 
Drawing, see annex 
 
Technical description 
Airflow direction 

Air intake over struts 

Rotational direction 
looking at rotor 

clockwise 

Frequency 

50 Hz 

60 Hz 

Nominal voltage 

230,0 V 

230,0 V 

Current consumption 

117 mA 

106 mA 

Power consumption 

19,5 W 

18,0 W 

Nominal voltage 

 

 

Current consumption 

 

 

Power consumption 

 

 

Speed 

2.600 1/min 

2.950 1/min 

Max. free-air flow 

146,0 m3/h 

170,0 m3/h 

Weight 

0,550 kg 

Protection class 

Max. torque when 
mounted across both 
mounting flanges 

wire outlet corner: 190 Ncm 
remaining corners: 310 Ncm 

Screw size 

ISO 4762 - M4 degreased, 
without an additional brace and 
without washer 

 
The product is intended for use in sheltered rooms with controlled 
temperature and controlled humidity. Directly exposure to water must 
be avoided. 
 
Pollution degree 1 (according DIN EN 60664-1) 
There is either no pollution or it occurs only dry, non-conductive 
pollution. The pollution has no negative impact. 
 
Ambient conditions 
 
Permitted ambient temperature 
Transport and storage 

Operation 
50 Hz 

60 Hz 

-40 °C ... 80 °C 

-10 °C ... 55 °C 

-10 °C ... 60 °C 

 
Vibration and shock load 
 
At stationary operation: 
 

sinus vibration 

1,0 g; 5 - 500 Hz; 3 x 1 sweep 
(Resonance search run) 

Noise 

0,5 m2/s3, 10 - 50 Hz; +12 
dB/oct f. 5 - 10 Hz; -12 dB/oct f. 
50 - 100 Hz; 3 x 30 min 

Repetitive shock 

Half sine; 5 g, 11 ms; 6 x 100 
shocks 

 
Transport and storage:  
 

Noise 

2,0 m2/s3, 5 - 20 Hz;  -3 dB/oct f. 
20 - 500 Hz; 3 x 30 min 

Thrusts 

Half sine; 18 g, 6 ms; 6 x 100 
shocks 

 
Do not operate your product in the resonance range.  

CONNECTION AND COMMISSIONING

 

 
Connect mechanical parts 
 

 

CAUTION 
Risk of cutting/squashing when 
removing the product from the 
packaging and during mounting. 
 
Grasp the housing and lift the product 
carefully out of the packaging. Avoid 
impact. 

 

Wear safety boots and cut-resistant 
gloves. 

 

 
 
 

Connect electrical parts 
 
Connect to the mains after installation. 
 

 

DANGER 
Do not touch. Risk of fatal injury 
from electrical current. 
 

 

Ensure that the electrical lines are 
de-energized. 

 

Secure the operating voltage against 
switching on again. 

 

Never work on parts that are 
energized. Only allow skilled 
electricians to work on the product. 

 

 

DANGER 
Compliance with the electrical 
installation regulations 
 

 

Observe the connection regulations 
that are valid in your country. (e.g. 
fusing, GFCI) 

 

 

CAUTION 
Electrical voltage 
The product is a built-in 
component and has no switch for 
disconnecting power.
 
 

 

Only connect the product to 
current circuits that can be 
switched off by a switch (all poles 
disconnected). When working on 
the product, secure the 
system/machine in which the 
product is installed against 
switching on again. 

 
 
NOTE 
Electromagnetic compatibility (EMC) may affect the system integration 
of the product due to interaction. 
 

 

Ensure the electromagnetic compatibility of the entire system. 

 
Ground fault interrupter GFI 
 

 

Only current-sensitive GFIs (type B) 
are permissible. Personal protection is 
not possible with GFIs when the 
product is in operation (see also 
frequency converters). 

 
 
 
Requirements: 
 
-  Before connecting the product, ensure that the supply voltage 

corresponds with the product voltage. 

-  Check whether the data on the nameplate corresponds with the 

interface data. 

 

Summary of Contents for 4650 N

Page 1: ... ratings are used in this operating manual to denote potential risk situations and important safety instructions DANGER This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed Observe this warning WARNING The dangerous situation can occur and can result in major or fatal injuries if the warning is not observed Work wit...

Page 2: ...er period of time we recommend running it for approx 15 minutes annually to move the motor bearings Cleaning NOTE Product damaged during cleaning Clean the product carefully with a moist cloth without applying pressure to the rotor Do not use cleaning agents that contain acids caustic solutions or solvents Disposal When disposing of the product observe all requirements and regulations that are rel...

Page 3: ...s Transport and storage Noise 2 0 m2 s3 5 20 Hz 3 dB oct f 20 500 Hz 3 x 30 min Thrusts Half sine 18 g 6 ms 6 x 100 shocks Do not operate your product in the resonance range 4 CONNECTION AND COMMISSIONING Connect mechanical parts CAUTION Risk of cutting squashing when removing the product from the packaging and during mounting Grasp the housing and lift the product carefully out of the packaging A...

Page 4: ...ct ebm papst Technical safety inspection What requires checking How to check Frequency Protection against accidental contact protective clothing Visual inspection min 1 2 yearly Check product for damage Visual inspection min 1 2 yearly Fixation of product Visual inspection min 1 2 yearly Fixation of wires Visual inspection min 1 2 yearly Fixation of protective earth connection Visual inspection mi...

Page 5: ...page 5 of 5 ...