background image

page 4 of 5 

 

 

 

 

Colour 

Operation 

Wire 1 

red 

+ UB 

Wire 2 

blue 

- GND 

Wire 3 

white 

Tacho 

 
The auxilliaries shown on the schematic diagram (which are required 
for the intended use) are not part of our delivery. 
 
Check connections 
 
NOTE 
 
DC-fans <=60V are products of Protection Class lll and must be 
operated with safety extra-low voltage. 
 
Connect product 
 
Check the product for visible damage and the operability of protective 
equipment before switching on. 
If damage is visible, do not start the product. 
 

FAULTS, POSSIBLE CAUSES AND REMEDIES

 

 
Replace your product by a new one, do not repair it. 
 

 

DANGER 

Electrical voltage at motor 
 

 

Wait five minutes after the voltage 
(all poles) has been switched off 
before opening the product. 

 
 
Fault/  
Error 

Possible cause 

Possible remedial 
action 

Mechanical 
blocking 

Switch off, de-energize 
and eliminate 
mechanical blocking. 

Mains voltage fault  Check mains voltage, 

re-connect voltage 
supply. 

Connection faulty 

Rectify connection, see 
pin connection. 

Motor is too hot 

Allow motor to cool / 
identify cause of fault. 

Motor winding 
interrupted 

Exchange product.  

Motor is not 
rotating 

Ambient 
temperature too 
high 

Reduce ambient 
temperature if possible. 

Impeller out of 
true 

Unbalance of 
rotating parts 

Clean product if still 
unbalanced after 
cleaning, exchange 
product. 

 

 

In case of further faults, contact ebm-
papst. 

 
Technical safety inspection 

 
What requires checking? 

How to 
check? 

Frequency 

Protection against accidental 
contact/ protective clothing 

Visual 
inspection 

min. 1/2 
yearly 

Check product for damage 

Visual 
inspection 

min. 1/2 
yearly 

Fixation of product 

Visual 
inspection 

min. 1/2 
yearly 

Fixation of wires 

Visual 
inspection 

min. 1/2 
yearly 

Insulation of wires 

Visual 
inspection 

min. 1/2 
yearly 

Check impeller for 
wear/sediments/ corrosion 

Visual 
inspection 

min. 1/2 
yearly 

 

APPROVALS

 

 
The product bears the CE mark. 
 
The CE mark is affixed to adequately sized nameplates. 
 
Within the meaning of the EMC Guideline 2004/108/EU this document 
is intended as: 
 

Mounting instructions as per Art. 9, Paragraph (3) 

Installation instructions as per Art. 3 

Operating manual as per Art. 9, Paragraph (3) 

Instructions for use as per Art. 8, Paragraph (2); Art. 9, Paragraph 
(5) 

Maintenance instructions as per Art.3; Art.9, Paragraph (3) 

Usage restrictions for residential areas as per Art.9, Paragraph (4) 
Accompanying documents as per Annex V, Cl. 3 
 
Within the meaning of Directive 2006/95/EU - use of electrical 
equipment within specific voltage limits - this document is intended 

Instructions for use Art. 10, Paragraph 1 

 
Within the meaning of the Directive 2006/42/EU Machine Guideline, 
this document is intended as 

Mounting instructions as per Art. 13, Paragraph 1b 

 
The information in this document and in the specification applies to 
mounting, installation, operation, use and maintenance. 

Reviews: