EVI
GB
17
www.eberg.eu
Turn ON
Plug in and turn on power switch, heater is in stand-by with buttons 1/2/3/4 on. Press button 4, heater
turns on, display shows current area temperature. But then button light 1/2/3 will disappear if no
operation within 10s.
Temp. Setting
Press button 1, temp. indicator flashes and its setting is activated. By pressing buttons 2/3, select
desired temp. (the temperature should be higher than room temperature), leave it for 5s. Heater starts
heating, display screen shows current temperature and button 5 lights on.
Press 2/3 on the remoter for required temp(the temperature should be higher than room temperature)
and then press Set button.
Setting Timer
Setting the time to start heating
In off-heating mode, press 1 twice to set timer( 0H to 24H), and 2 or 3 to set temperature. After setting, it
shows area temperature. Indicator 8 lights on in timer period and off when timer ends, then heater starts
heating at high level.
Setting the end time of heating
In heating mode( high or low level), press button 1 twice to set timer and buttons 2 or 3 to set temperature.
After setting, it shows area temperature. Indicator 8 lights on in timer period and off when timer ends.
Then heater stops heating.
High/Low Heat Setting
• In working mode, button 2 shifts between high heating and stop heating (indicator 7 lights on when
high heating and off when off heating); 5 High/Low Heat Selection.
• In working mode, button 3 runs between low heating and off heating (indicator 6 lights on when low
heating and off when off heating);
• In working mode, button 12 shifts among Off/Low/High heating, (indicator 7 lights on in high heating,
6 light on in low heat, and no light on when off heating).
Child-lock Setting
Press both 2 and 3 for 3s, system is locked and no setting could be done. After 3 s, display shows again area
temperature. Methods to unlock: Press both 2 and 3 for 3s, the unit is unlocked.
Display buttons activation
Normally display buttons light are off when unit is working, touch the panel area below temperature, they
are on again.
ECO Function
Press both setting button 1 and 3 for 3s ( or press button 11 on remote control), ECO function runs. In this
mode, display shows only some indicators ( depending on what setting shave been done before ECO).
Methods to lock ECO function:
1) Press any button on display
2) Press ECO button 11 on remote control.
Switch the display between °C/F
Press the keys 1 & 2 (the two keys on the left) simultaneously for about 10 seconds.
Open-window Detection
If temperature decreases 3°C or more in 2 mins. , open-window detection acts and, unit stops
heating,
indicator 9 flashes. Press button 4, turn off heater then turn on again open-window detection is closed.