EBARA OPTIMA/BEST-RIGHT-DW Operating And Maintenance Manual Download Page 3

7

EN

5.1. INSTALLATION (FIG.1-5)

To install the pumps, proceed as directed in PART 1, chapter 

7.2 and in the following point:
a)  It is best to use rigid pipes (metal pipes on DW series) for 

permanent installations and flexible pipes for temporary 

installations, with sizes as given in chap. 4, observing the 

distances illustrated.

5.2. INSTALLING DW PUMP WITH DN 50 FLANGE (FIG. 6-7)

a)  Using the relevant screws, fasten the mount on the sur

-

faces due to support the pump;

b) screw the delivery pipe onto the mount;

c)   the mount features a rod with a guide along which you 

slide the hook required to lower the pump;

d)  lower the motor-driven pump, holding it by the rope fas

-

tened around the handle, until the flange slots into place 

on the mount;

e)  the motor-driven pump couples with the mount under its 

own weight.

6. STARTING

New  pumps  may  feature  a  small  amount  of  oil  (the  food 

kind), which does not present a source of health risk.

6.1. VERSION WITH FLOAT (MA-MS) (SEE FIGURE)

Plug into the power mains and/or turn on with the switch: 

the  motor-driven  pump  starts  working.  Once  the  pump 

has sucked in enough water to reach the minimum level 

(“OFF” level), regulated by the float, it will turn off auto

-

matically.

The float’s working position is factory set so as to assure a 

minimum immersion level in the “OFF” position.

NB: If the liquid is overly contaminated, the operation of the 

magnetic-type  float  (MS  versions)  may  be  compromised, 

meaning it needs to be cleaned on a regular basis.

Moreover,  do  not  use  in  liquids  polluted  with  iron  dust  or 

magnetic material as this would compromise the operation 

of the float.

6.2. VERSION WITHOUT FLOAT

Plug into the power mains and/or turn on with the switch: 

the motor-driven pump starts working. Once the pump has 

sucked in enough water to reach the minimum level, unplug 

from the power mains and/or turn off with the switch.

6.3. RIGHT - DW PUMPS

a)  There is a vent hole on the side of the pump casing of 

RIGHT  and  DW  versions  for  priming.  During  operation, 

there will be a small recycling jet from it.

b)  The  three-phase  version  of  the  DW  pumps  features 

 

a  3-wire  +  earth  power  cord  with  the  addition  of  two 

white  and  grey  wires  with  a  smaller  cross-section  con

-

nected to the thermal overload protector inside the mo

-

tor (FIG. 13).

  –  

Connect  the  power  cord’s  yellow/green  wire  to  an  ef

-

ficient earthing system, which must be in compliance 

with the regulations in force in the user’s country;

  –  

overload protection and use of the signal provided by 

the thermal overload protector are the user’s responsi

-

bility;

  –  

overload trip units must have suitable thermal-magnet

-

ic devices set appropriately for the motor-driven pump 

installed;

  –  

for the heat sensor, the two white and grey wires must 

be connected to an electrical circuit that can cut power 

to the motor-driven pump.

7. MAINTENANCE

To maintain the motor-driven pumps properly and ensure 

their long service life, the filter and/or suction port must 

not be clogged and the impeller must be clean.

During maintenance work on the motor-driven pumps, dis-

connect the power supply.

7.1.  OPTIMA - BEST ONE - ONE VOX MOTOR-DRIVEN PUMP 

(FIG. 8)

To reach the impeller, proceed as follows:

–  wear work gloves to avoid cutting your hands;

–  unscrew the two screws (1) securing the filter;

–  remove the filter (2);

–   unscrew the two spacers (3) and remove the volute (5); 

–   using  a  small  straight  screwdriver,  remove  the  nylon 

washers (4) and replace with new ones;

–  take care not to damage the O-ring (6).

At this point, the impeller is exposed: make sure it is clean.

7.2. BEST 2-5 MOTOR-DRIVEN PUMPS (FIG. 9)

To reach the impeller, proceed as follows:

–  wear work gloves to avoid cutting your hands;

–  unscrew the three screws (1) securing the filter;

–  remove the filter (2);

–   unscrew the three spacers (4) and three nuts (5) and re

-

move the distancing plate (3);

–   using  a  small  straight  screwdriver,  remove  the  nylon 

washers (6) and replace them before reassembling the 

unit as they break when the volute is removed;

–  take care not to damage the O-ring (7).

7.3. RIGHT MOTOR-DRIVEN PUMP (FIG. 10)

a)  If the suction port is clogged, you must clean it, remem

-

bering to wear work gloves at all times to avoid cutting 

your hands;

b)  If the impeller is dirty, proceed as follows:

  – wear work gloves to avoid cutting your hands;

  –  unscrew the three screws (1) securing the feet and suc

-

tion cover side (2)

  – remove the O-ring (3);

  – take care not to damage the O-ring (3); 

  –  make sure the space between the impeller and casing 

is also clean.

c)   There is a small opening in the pump casing for air vent

-

ing; keep it unclogged and clean. It is normal for fluid to 

come out during priming.

7.4. DW MOTOR-DRIVEN PUMP (FIG. 11)

a)  If the suction port is clogged, you must clean it, remem

-

bering to wear work gloves at all times to avoid cutting 

your hands;

b)  If the impeller is dirty, proceed as follows:

  – wear work gloves to avoid cutting your hands;

  –  unscrew  the  six  screws  (1)  keeping  the  pump  casing 

closed (not the nut as it is welded to the pump casing);

  – remove the pump casing, pulling it off (2);

  – remove the O-ring (3);

  –  take care not to damage the O-ring (3);

  –  make sure the space between the impeller and casing 

is also clean.

7.5. REASSEMBLY

To reassemble, repeat the procedure given in reverse order.

Summary of Contents for OPTIMA/BEST-RIGHT-DW

Page 1: ...ENIE ORYGINALNEJ INSTRUKCJI Instrukcja użytkowania i konserwacji 30 DALGIÇ ELEKTRO POMPALAR OPTIMA BEST RIGHT DW ORIJINALTALIMATLARIN ÇEVIRI Kullanım ve Bakım kılavuzu 36 NEDSÄNKBARA ELPUMPAR OPTIMA BEST RIGHT DW ÖVERSÄTTNINGAV DEN URSPRUNGLIGABRUKSANVISNINGEN Instruktionsbok för drift och underhåll 14 DYK ELEKTROPUMPE OPTIMA BEST RIGHT DW OVERSÆTTELSEAF DEN ORIGINALE BRUGSANVISNING Brugs og vedli...

Page 2: ...tanks and trenches etc WARNING ONLY USE RIGHT AND DW SERIES MOTOR DRIVEN PUMPS FOR CONTINUOUS DUTY IF THEY ARE FULLY SUBMERSED DO NOT USE RIGHT DW MOTOR DRIVEN PUMPS WITH THE MOTOR OUT OF WATER FOR MORE THAN 15 MINUTES Use the motor driven pumps based on their technical speci fications 3 3 USE FOR WHICH PUMPS ARE NOT DESIGNED The pumps cannot be used to handle water containing acids or bases and c...

Page 3: ...al overload protector are the user s responsi bility overload trip units must have suitable thermal magnet ic devices set appropriately for the motor driven pump installed for the heat sensor the two white and grey wires must be connected to an electrical circuit that can cut power to the motor driven pump 7 MAINTENANCE To maintain the motor driven pumps properly and ensure their long service life...

Page 4: ...ΗΣ 8 SCHÉMA INSTALACE A DEMONTÁŽE 8 SCHÉMA INŠTALÁCIE A DEMONTÁŽE 8 SCHEMAT INSTALACJI I DEMONTAŻU 8 МОНТАЖНЫЕ И ДЕМОНТАЖНЫЕ СХЕМЫ 8 SCHEMĂ INSTALARE ŞI DEMONTARE 8 MONTAJ VE SÖKME ŞEMASI 8 8 СХЕМА ЗА ИНСТАЛИРАНЕ И ДЕМОНТИРАНЕ 8 PAIGALDUS JA DEMONTEERIMISE SKEEMID 8 UZSTĀDĪŠANAS UN DEMONTĀŽAS SHĒMA 8 MONTAVIMO IR IŠMONTAVIMO SCHEMA 8 TELEPÍTÉSI ÉS SZÉTSZERELÉSI RAJZ 8 СХЕМА МОНТАЖУ ТА ДЕМОНТАЖУ 8 ...

Page 5: ...61 FIG 8 OPTIMA BEST ONE BEST ONE VOX FIG 9 BEST 2 3 4 5 FIG 10 FIG 10 RIGHT RIGHT FIG 11 DW DW VOX FIG 12 FIG 13 ...

Page 6: ... Černý 3 Blå grå 3 Sininen harmaa 3 Blauw grijs 3 Azul cinzento 3 Μπλε γκρι 3 Modrý šeda 4 Brun 4 Ruskea 4 Bruin 4 Castanho 4 Καφέ 4 Hnědý 5 Kabelklemme 5 Johdonkiristin 5 Kabelklem 5 Passa Fios 5 Στυπειοθλίπτης 5 Kabelová úchytka 6 Jordforbindelsesskrue 6 Maadoitusruuvit 6 Aardingsschroeven 6 Parafuso de terra 6 Βίδα γείωσης 6 Zemnící šroub SK PL RO RU T 1 Žlto zelený 1 Żółto zielony 1 Galben ver...

Page 7: ...Tel 48 22 3909920 Fax 48 22 3909929 e mail mktgpl ebaraeurope com EBARA Pumps Europe S p A GERMANY Elisabeth Selbert Straße 2 63110 Rodgau Germany Tel 49 0 6106 66099 0 Fax 49 0 6106 66099 45 e mail mktgd ebaraeurope com EBARA Pumps RUS Ltd Prospekt Andropov 18 building 7 floor 11 115432 Moscow Tel 7 499 6830133 e mail mktgrus ebaraeurope com EBARA PUMPS IBERIA S A Poligono Ind La Estación C Cormo...

Reviews: