Leakage Detector
(Does not apply to Model DGUII.)
1. Construction:
Each switch has a magnet-containing float which senses the liquid level and magnetically actuates a dry
reed switch encapsulated within a stem. The switch opens on rise of liquid. Leakage detector should be wired
into control circuit to disconnect power to pump when activated.
2. Specifications
• Apply to 2 to 10HP
Lead Wire
Float Body
(Polypropylene)
Float
(Polypropylene)
Stopper
(316 S.S.)
Open
Close
Breaking Capacity
: AC50VA, DC50W
Max. Breaking Current
: AC0.5A, DC0.5A
Max. Operating Voltage
: AC300V, DC300V