background image

noteS

taBULar Data

 1. 

measurement/Data Processing Systems:

 Primary - FChart: proprietary EAW software; Secondary - Brüel & Kjær 2012.

 2. 

microphone Systems:

 Earthworks M30; Brüel & Kjær 4133

 3. 

measurements:

 Dual channel FFT; length: 32 768 samples; sample rate: 48 kHz; logarithmic sine wave sweep.

 4. 

Measurement System Qualification

 (includes all uncertainties)

:

 SPL: ac/-0.2 dB @ 1 kHz, pre/-0.5 dB 20 Hz to 20 kHz, resolution 0.05 dB; Frequency: ac/-1 %, pre/-0.1    

    Hz, resolution the larger of 1.5 Hz or 1/48 octave; Time: ac/-10.4 μs, pre/-0.5 μs, resolution 10.4 μs; Angular: ac/-1°, pre/-0.5°, resolution 0.5°.
 5. 

environment:

 Measurements time-windowed and processed to eliminate room effects, approximating an anechoic environment. Data processed as anechoic or fractional space, as noted.

 6. 

measurement Distance:

 7.46 m. Acoustic responses represent complex summation of the subsystems at 20 m. SPL is referenced to other distances using the Inverse Square Law.

 7. 

enclosure orientation:

 For beamwidth and polar specifications, as shown in Mechanical Specification drawing.

 8.  

Volts:

 Measured rms value of the test signal.

 9.  

Watts:

 Per audio industry practice, “loudspeaker watts” are calculated as voltage squared divided by rated nominal impedance. Thus, these are not True Watt units of energy as defined

    by International Standard.
 10. 

SPL:

 (Sound Pressure Level) Equivalent to the average level of a signal referenced to 0 dB SPL = 20 microPascals.

 11. 

Subsystem:

 This lists the transducer(s) and their acoustic loading for each passband. Sub = Subwoofer, LF = Low Frequency, MF = Mid Frequency, HF = High Frequency.

 12. 

operating mode:

 User selectable configurations. Between system elements, a comma (,) = separate amplifier channels; a slash (/) = single amplifier channel. DSP = Digital Signal Processor.

    IMPORTANT: To achieve the specified performance, the listed external signal processing must be used with EAW-provided settings.
 13. 

operating range:

 Range where the processed Frequency Response stays within -10 dB SPL of the power averaged SPL within this range; measured on the geometric axis. Narrow band

    dips are excepted.
 14. 

nominal Beamwidth:

 Design angle for the -6 dB SPL points, referenced to 0 dB SPL as the highest level.

 15. 

axial Sensitivity:

 Power averaged SPL over the Operating Range with an input voltage that would produce 1 W at the nominal impedance; measured with no external processing on  

 

 

    the geometric axis, referenced to 1 m.
 16. 

nominal Impedance:

 Selected 4, 8, or 16 ohm resistance such that the minimum impedance point is no more than 20% below this resistance over the Operating Range.

 17. 

accelerated Life test:

 Maximum test input voltage applied with an EIA-426B defined spectrum; measured with recommended signal processing and Recommended Protection Filter.

 18. 

calculated axial output Limit:

 Highest average and peak SPLs possible during the Accelerated Life Test. The Peak SPL represents the 2:1 (6 dB) crest factor of the Life Test signal.

 19. 

High Pass filter:

 This helps protect the loudspeaker from excessive input signal levels at frequencies below the Operating Range.

GraPHIc Data

 1. 

resolution:

 To remove insignificant fine details, 1/12 octave cepstral smoothing was applied to acoustic frequency responses and 1/3 octave cepstral smoothing was applied to the beamwidth and  

 

    impedance data. Other graphs are plotted using raw data.
 2. 

frequency responses:

 Variation in acoustic output level with frequency for a constant input signal. Processed: normalized to 0 dB SPL. Unprocessed inputs: 2 V (4 ohm nominal impedance), 2.83 V (8    

    ohm nominal impedance), or 4 V (16 ohm nominal impedance) referenced to a distance of 1 m.
 3. 

Processor response:

 The variation in output level with frequency for a constant input signal of 0.775 V = 0 dB reference.

 4. 

Beamwidth:

 Average angle for each 1/3 octave frequency band where, starting from the rear of the loudspeaker, the output first reaches -6 dB SPL referenced to 0 dB SPL as the highest level. This method  

    means the output may drop below -6 dB SPL within the beamwidth angle.
 5. 

Impedance:

 Variation in impedance magnitude, in ohms, with frequency without regard to voltage/current phase. This means the impedance values may not be used to calculate True Watts (see 9 above).

 6. 

Polar Data:

 Horizontal and vertical polar responses for each 1/3 octave frequency band 100 Hz to 16 kHz or Operating Range.

VFS250i

  

Specifications

     

 Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com

August 2013

Part Number: RD0765 Rev 100

EAW products are continually improved.  All specifications are therefore subject to change without notice. 

InPUt PaneL

SIGnaL DIaGram

LeGenD

DSP

:   

EAW UX8800 Digital Signal Processor –or– Integral Digital Signal Processing for NT products.

HPf:

 

High Pass Filter for crossover –or– Recommended High Pass Filter.

LPf:

 

Low Pass Filter for crossover.

Lf/mf/Hf:

 

Low Frequency / Mid Frequency / High Frequency.

amP:

  

User Supplied Power Amplifier –or– Integral Amplifier for NT products.

XVr:

 

Passive LPFs, HPFs, and EQ integral to the loudspeaker.

eaW focusing: 

Digital Signal Processor capable of implementing EAW Focusing.

DSP 

EQ 

HPF 

LPF 

AMP

1-Way, Single-Amp (LF1/LF2)

LF

LF

THIS PRODUCT HAS M10 MOUNTING POINTS. SEE OWNER’S MANUAL.

PIN 1−...−

PIN 1+...+

+

REV:

DESCRIPTION:

REVISIONS

A00

NEW ISSUE PER ECOWHT8165 MJC 

DWG SPEC/INPUT RATH

SCALE:

2037638-SD

MJC

12/6/11

DRAWING NUMBER:

DATE:

DRAWN BY:

1 of 1

1:1

REV:

A00

LOUD TECHNOLOGIES INC, ALL RIGHTS RESERVED

ONE MAIN STREET, WHITINSVILLE, MA 01588 USA

LOUD Technologies Inc.

TITLE:

SHEET:

ADOBE ILLUSTRATOR

Reviews: