background image

6

 – CXA120

CXA120 – 

7

14. INPUT TERMINALS

The Input has a balanced screw terminal connector that 

accepts an audio line-level mono signal. The screw 

terminals should be connected as shown in the following 

figures:

      Balanced connection:

HOT (+) connects to BAL1, Cold (-) connects to BAL 2, and 

the shield connects to COM.

Strip the wire back about 1/2" inch, loosen the screw 

enough to loop the wire around the shaft of the screw 

(clockwise), and tighten down the screw with either a slot-

head or phillips-head screwdriver. 

Use high-quality, three-conductor shielded cable for 

balanced connections. The better the shield, the better the 

audio signal is protected from induced EMI and RFI.

      Unbalanced connection:

If connecting an unbalanced line-level signal to the Input, 

wire the connections as shown in the following figure:

HOT (+) connects to BAL1, the shield connects to COM, and 

an insulated jumper connects COM to BAL2.

BAL1 COM BAL2

TEL PAGING

T

R

G

COM

JUMPER

SHIELD

HOT (+

)

BAL1 COM BAL2

TEL PAGING

T

R

G

COM

SHIELD

SHIELD

HOT (+

)

COLD (--)

15. TELEPHONE PAGING TERMINALS

These 300 ohm input terminals allow you to connect an 

auxiliary input. The volume level of this input is adjusted 

using the rear panel TEL VOL (11) level control.

Any signals present at these terminals take voice priority 

over the main input. An internal adjustment pot is provided 

for adjusting the threshold of the voice priority circuit (see 

page 10). 

16. GROUND (EARTH) SCREW

The chassis connects to ground via the AC ground, and 

normally does not need any extra ground connection. 

Connections, if required, should be made by experienced, 

qualified electricians.

Summary of Contents for POWER AMPLIFIER CXA120

Page 1: ...CXA120 Power Amplifier INSTRUCTION MANUAL 2004 LOUD TECHNOLOGIES INC EAW IS A REGISTERED TRADEMARK OF LOUD TECHNOLOGIES INC CXA120 AMPLIFIER CXA120 AMPLIFIER...

Page 2: ...let unless the blades can be fully inserted to prevent blade exposure Pour pr venir les chocs lectriques ne pas utiliser cette fiche polarise avec un prolongateur un prise de courant ou une autre sort...

Page 3: ...tant voltage The smart output stage is fully protected against permanent damage caused by overloading shorts and extreme temperatures The CXA120 operates on either 115 or 230 VAC 50 60Hz determined by...

Page 4: ...VOLUME Use this volume control to adjust the sound output level to your speakers 4 LED METER This meter shows the signal output level The left five LEDs represent the area between 20 dB and 0 dB Adju...

Page 5: ...INPUT SENSITIVITY This adjusts the gain of the input section If you have a weak input signal leave this switch out If you have a strong signal press this switch in 11 TEL VOLUME This controls the volu...

Page 6: ...V 70 V or 100 V output terminal to the side of the speaker system and connect the COM output terminal to the side of the speaker system The voltage of your speakers must equal the voltage of the ampli...

Page 7: ...an unbalanced line level signal to the Input wire the connections as shown in the following figure HOT connects to BAL1 the shield connects to COM and an insulated jumper connects COM to BAL2 BAL1 CO...

Page 8: ...hind the chassis to allow proper ventilation If the amplifier should overheat a thermal switch turns off the power amplifier allowing the heatsinks to cool down Once the amplifier has cooled to a safe...

Page 9: ...CXA120 9 1202 VLZPRO 2004 LOUD TECHNOLOGIES INC EAW IS A REGISTERED TRADEMARK OF LOUD TECHNOLOGIES INC CXA120 AMPLIFIER MIXER OR PREAMPLIFIER 7 TYPICAL HOOKUP DIAGRAM...