background image

Eastern Acoustic Works’ Product Usage Guide: 
An Introduction

This is the sixth installment in the Eastern Acoustic Works
Product Usage Guide series. The goal of this series is to offer
concise, accurate guidance on the use EAW loudspeaker
products. 

Each guide will offer a concise overview of a particular

product series and illustrate the most common methods of
use. Complementary systems, such as subwoofers, will be
recommended for each system and the appropriate MX
Series Close Coupled Processor configuration for each 
combination will be discussed.

This chapter will focus on the MQ Series of dedicated

mid/high and low frequency VA

4

loudspeaker systems.

MQ Series Systems

The MQ Series of loudspeakers are specifically designed for
high-performance in permanent installations. This guide
will explain some of the performance features and capabili-
ties and show how MQ Series loudspeakers can be used in a
variety of different ways.

MQ Series Background and Description

The MQ Series comprises an integrated set of biamplified
two-way mid/high frequency modules and low frequency
modules optimized to array with them in specific combina-
tions. The MQ Series is intended exclusively for permanent
installations. Each mid/high module uses one or two horn-
loaded VA

4

10-in mid cone/radial phase plug assemblies and

a 2-in exit/75mm horn-loaded HF compression driver.
Horn-loading of the mid and high frequency drivers allows
the MQ Series modules to maintain accurate pattern control
over their operating bandwidths. This lets the modules array
with minimal interference and makes them suitable for a
variety of applications where fidelity, control and high 
output are required. Beamwidth vs. Frequency charts are 
presented in the appendix to this Application Guide.

The MQ Series mid/high modules offer a variety of 

horizontal and vertical dispersion patterns. Table 1 below
summarizes the primary specifications.

MQ1364

MQ1366

MQ1394

MQ2364

MQ2394

Coverage

60°x40°

60°x60°

90°x40°

60°x40°

90°x40°

(H x V)

MF Cone(s)

1x 10-in

1x 10-in

1x 10-in

2x 10-in

2x 10-in

(horn-loaded)

Nominal

8 Ohms

8 Ohms

8 Ohms

4 Ohms

4 Ohms

Impedance

Sensitivity

109.5 dB SPL

109.5 dB SPL

108.5 dB SPL

112.0 dB SPL

111.0 dB SPL

(1W @ 1m)

Power 

400 Watts

400 Watts

400 Watts

800 Watts

800 Watts

Handling

(AES Standard)

HF Compression

1x 2-in exit

1x 2-in exit

1x 2-in exit

1x 2-in exit

1x 2-in exit

Driver

(horn-loaded)

Nominal

8 Ohms

8 Ohms

8 Ohms

8 Ohms

8 Ohms

Impedance

Sensitivity

114.0 dB SPL

112.0 dB SPL

110.5 dB SPL

114.0 dB SPL

110.5 dB SPL

(1W @ 1m)

Power 

200 Watts

200 Watts

200 Watts

200 Watts

200 Watts

Handling

(AES Standard)

Summary of Contents for MQ1364

Page 1: ...T h e L a w s o f P h y s i c s T h e A r t o f L i s t e n i n g P R O D U C T U S A G E G U I D E f o r MQ Series Systems ...

Page 2: ...nt installations Each mid high module uses one or two horn loaded VA4 10 in mid cone radial phase plug assemblies and a 2 in exit 75mm horn loaded HF compression driver Horn loading of the mid and high frequency drivers allows the MQ Series modules to maintain accurate pattern control over their operating bandwidths This lets the modules array with minimal interference and makes them suitable for ...

Page 3: ...ter LF Cone s 3x 12 in 4x 12 in 2x 8 in 2x 12 in 2x 12 in 2x 15 in 2x 18 in 2x 18 in Nominal 3x 8 2x 4 2x 12 2x 8 2x 8 2x 8 4 4 Impedance Ohms Sensitivity 97 97 101 101 101 101 99 99 1W 1m dB SPL Power 1500 2000 400 1000 1000 1600 2000 2000 Handling AES Standard Watts Specific low frequency and sub bass modules complement the MQ Series systems to create three or four way arrays Table 2 below summa...

Page 4: ...per cabinet 6 each on the top bottom and sides SB1000e 4 3 Position Flytracks 2 per side The integral mounting suspension facilities can be used with either commercially available or custom fabricated suspension systems Any suspension systems should be reviewed by a qualified structural engineer to ensure adequate safety and compliance with local codes Processors EAW MX Series processors are facto...

Page 5: ...cluster used for auditorium church etc 2x MQ1364 separated by 1x MQ1312 with 1x MQ1394 for downfill This system is desirable when off axis radiation from the LF system is needed to cover the downfill area Figure 3 Medium cluster used for larger auditorium church or sports facility 2x MQ1364 separated by 1x TD412 with 1x MQ1394 for downfill This system offers enhanced low frequency pattern control ...

Page 6: ...15 with 1x MQ1394 for downfill This system offers enhanced low frequency pattern control It is best suited to reverberant spaces and to applications where the primary microphone position is directly below the cluster Figure 6 Very large cluster used for major league sports facility 2x MQ2364 separated by 1x MQ2412 over 2x MQ1364 separated by 1x MQ1312 for downfill The overall system provides very ...

Page 7: ...1000 10000 20000 Beamwidth Degrees Frequency Hz Horizontal Vertical MQ1364 0 30 60 90 120 150 180 210 240 270 300 1000 10000 20000 Beamwidth Degrees Frequency Hz Horizontal Vertical MQ1366 0 30 60 90 120 150 180 210 240 270 300 1000 10000 20000 Beamwidth Degrees Frequency Hz Horizontal Vertical MQ1394 0 30 60 90 120 150 180 210 240 270 300 1000 10000 20000 Beamwidth Degrees Frequency Hz Horizontal...

Page 8: ...itinsville MA 01588 tel 800 992 5013 508 234 6158 fax 508 234 8251 web http www eaw com EUROPE EAW International Ltd tel 44 1494 539090 fax 44 1494 539091 T h e L a w s o f P h y s i c s T h e A r t o f L i s t e n i n g ...

Reviews: