
Cable:
2 conductor plus shield
Mating Connector:
XLR-3 male
PIN 1
Shield
PIN 2
Plus / Hot
PIN 3
Minus / Cold
6.1.2
DIGITAL SIGNAL INPUT CONNECTION
The two XLR-type connectors used for analog audio signals are also used for digital audio signals.
These are designed for the AES/EBU digital signal (AES3 Standard). Use the female XLR as the signal
input. Use the male XLR as a loop-thru output to connect the same signal input to additional JF
NT
/JF
NT
s.
To use these connectors for digital audio input signals, repeatedly press the associated momentary
INPUT SELECT switch, cycling through the LED indications until either the AES/EBU Ch 1 or the
AES/EBU Ch 2 LED is illuminated.
Channel 1 and Channel 2 are also referred to as Subframe 1 and Subframe 2.
Cable:
2 conductor plus shield
Mating Connector:
XLR-3 male
PIN 1
Signal earth (shield)
PIN 2
Signal
PIN 3
Signal
IMPORTANT: Looping an AES/EBU signal to another JF
NT
/KF
NT
or other audio device’s
analog input will result in audible noise at potentially high levels. Make sure the downstream
service input accepts an AES/EBU (AES3) digital input signal.
6.1.3
USB CONNECTION
The standard USB connection on the rear of the JF
NT
/KF
NT
is designed to connect a computer with
the EAWPilot control program installed. Subsequent JF
NT
/KF
NT
s are connected using the U-Net
ports. EAWPilot provides user-adjustable control over individual elements in the array and over the
array as a whole.
Port Type:
USB 1.1
Cable:
Standard USB 2.0 Cable Type A to B supplied (maximum 15 ft / 3 m
without active repeaters. A 6 ft / 2 m USB cable is supplied)
Mating Connector:
USB type "B" connector
6.1.4
U-NET NETWORK CONNECTION
The two, identical, locking Neutrik EtherCon connectors on the rear of each JF
NT
/KF
NT
combine a
RJ45 connector with a locking shell. They are designed for connecting EAW’s audio and control
signals between additional JF
NT
/KF
NT
s and other U-Net enabled devices. Either connector may be
used as the ports are bi-directional. In addition they auto-sense the cable wiring configuration
(standard or crossover).
Cable:
Ethernet CAT-5 or better (300 feet / 91 meters)
Mating Connector:
RJ45 with or without Neutrik NE8MC cable carrier
Wiring Configuration:
Standard or crossover cable (ports auto-sense cable configuration)
Green Status LED:
Indicates communication is established between two devices
Red Status LED:
Indicates a network error. A solid red LED indicates there is an error
somewhere in the network. A blinking red LED indicates the device
that is causing the error.
To use the U-Net input signal, repeatedly press the associated momentary INPUT SELECT switch
cycling through the LED indications until all three LEDs are illuminated.
Note:
EAWPilot must be used to select the U-Net audio channel and configure the U-Net audio routing.
ALL ON = U-NET INPUT
INPUT SELECT
FLASHING = USER DSP ENABLE
CONSTANT = USER DSP DISABLE
AES/EBU
RIGHT
AES/EBU
LEFT
NORM/
ANALOG
INPUT
LOOP
2
3 Signal -
2
3 Signal -
1
Shield
1
PUSH
ALL ON = U-NET INPUT
INPUT SELECT
FLASHING = USER DSP ENABLE
CONSTANT = USER DSP DISABLE
AES/EBU
RIGHT
AES/EBU
LEFT
NORM/
ANALOG
INPUT
LOOP
2
1
3
3
2
1
2 Signal
3 Signal
2 Signal
3 Signal
Signal
Earth
(cable
shield)
13