EAW DX8 Quick Start Manual Download Page 2

B

REMOTE BUS

TRIM

BUS A

U

+20

-20

A

TRIM

1

RECORD

A

B

OUTPUTS

LOGIC I/O

TRIM

BUS B

U

+20

-20

TRIM

2

TRIM

3

TRIM

4

TRIM

5

TRIM

6

TRIM

7

TRIM

8

MIC

GAIN

0

60


+

SERIAL NUMBER

MANUFA

MANUF

MANUF CTURING D

A

A

AT

CTURING D

CTURING D E

COMM PORT

DIRECT OUTPUTS

POWER

INPUT

22-28V DC,

3A MAX

2 3 4 5 6 7 8

1

+ G

G +

MIC

LINE

LINE

LINE

LINE

MIC

LINE

MIC

LINE

MIC

LINE

MIC

LINE

MIC

LINE

MIC

LINE

MIC

LINE

MIC

-30dB +30dB

U

MIC

GAIN

0

60

-30dB +30dB

U

MIC

GAIN

0

60

-30dB +30dB

U

MIC

GAIN

0

60

-30dB +30dB

U

MIC

GAIN

0

60

-30dB +30dB

U

MIC

GAIN

0

60

-30dB +30dB

U

MIC

GAIN

0

60

-30dB +30dB

U

MIC

GAIN

0

60

-30dB +30dB

U

PHANTOM POWER

48V DC

12

1 +5V

11

G

1

G +

G +

G +

INPUTS

OUTPUTS

100

240V      , 50/60Hz, 1A MAX

0V      , 50/60Hz, 1A MAX

LISTED COMMERCIAL 

LIS

LIS

AUDIO EQUIPMENT

9Z39

R

DX8 DIGITAL MIXER

FRONT PANEL FEATURES 

AND CONTROLS

   INPUT UP/DOWN BUTTONS

        Use to adjust the mix level for each 

input channel to Output A or B.

   INPUT LED DISPLAY

        This indicates the signal level after the 

mic preamp stage, just after the A/D 

converter. When any input UP/DOWN 

button is pressed, the input meters 

switch from level metering to level 

setting indication. After fi ve seconds, the meter 

switches back to normal level (PPM) metering.

   EQ LO/HI UP/DOWN BUTTONS

        Use to adjust the gain of the 2-band shelving EQ on 

Outputs A or B.

   EQ LED DISPLAY

        When an EQ UP/DOWN button is pressed, the EQ 

meter indicates the amount of boost or cut of the 

LO and HI frequencies in decibels (±15 dB).

   MASTER A/B UP/DOWN BUTTONS

        These buttons adjust the output level for each 

output bus.

   MASTER OUTPUT LED DISPLAY

        This indicates the signal level after the digital 

signal processing and MASTER gain stage. When a 

MASTER UP/DOWN button is pressed, the master 

output meter switches from level metering to level 

setting indication. After fi ve seconds, the meter 

switches back to normal (PPM) level metering.

   MODE

        Changes the front panel buttons between Bus A 

and Bus B operation. The LOCK position disables 

the front panel controls to prevent unauthorized 

changes to the settings. The default lock code 

(1234) can be changed with the DX8-PC application.

   COMM PORT

        An RS-232 port on a 9-pin D-Sub connector, which 

connects to a personal computer or other compatible 

control system for external control of the DX8 set-

tings.

   POWER

        Use the POWER switch to turn the DX8 on and off.

OL

2
4
7

10

OL

2
4
7

10

OL

2
4
7

10

OL

2
4
7

10

OL

2
4
7

10

OL

2
4
7

10

12

15

9
6
3

2

OL

4
7

10

A

B LOCK

MODE

POWER

COMM PORT

1

2

3

4

5

6

7

8

HI

LO

EQ

B

A

MASTER

DX8 DIGITAL MIXER

REAR PANEL FEATURES 

AND CONTROLS

  INPUTS 1-8

        Each of the eight analog inputs has separate bal-

anced mic and line input connectors that use XDR 

mic preamps. These are 3-pin Phoenix-type connec-

tors. Use either the MIC or LINE input; only one can 

be used per channel.

  TRIM

        Use to trim the level of the input signal for optimum 

signal-to-noise ratio in the preamp stage. 

  PHANTOM POWER

        These switches apply phantom power (+48VDC) 

to pins 2 and 3 of the selected mic input connec-

tors. Switch the PHANTOM POWER switch for an 

individual channel to the UP position when using a 

condenser microphone.

  BUS A/B INPUTS

        These analog inputs accept balanced line-level 

signals and route the signal to the internal buses. 

There is no DSP processing on these inputs.

  BUS A AND B TRIM

        Use to trim the level of the inputs to the buses.

  DIRECT OUTPUTS

        This 15-pin D-Sub connector supplies an analog, 

unbalanced line-level signal from each of the eight 

program inputs, post-preamp and pre-processing.

  RECORD OUT

        These RCA connectors supply unbalanced line-level 

signals from the BUS A and BUS B outputs. The 

signals are the same as the main outputs.

  OUTPUTS A/B

        These 3-pin Phoenix-type connectors supply a bal-

anced line-level signal from BUS A and BUS B.

  LOGIC I/O

        This 25-pin D-Sub connec-

tor provides 10 logic control 

inputs and 10 logic control 

outputs (open-collector). These 

inputs can be used to control a 

wide variety of DX8 functions 

via external switching. The 

outputs can be used to provide 

status levels for external indi-

cators for a number of internal 

settings and conditions, as well as control switching 

to external devices.

  REMOTE BUS

        This 3-pin Phoenix-type connector can be used to 

attach optional remote controls to the DX8. Several 

remote controls can be connected to each other in 

a daisy-chain fashion to extend the remote control 

functionality of the DX8.

  COMM PORT

        This is identical to the COMM PORT on the front panel. 

Use this to connect to an RS-232 serial port on a 

personal computer or third-party controller for external 

control of the DX8.

  EXPANSION SLOT

        This is used for the DX810 to install the DX•10e 

expansion board, which provides additional DSP 

horsepower and eight more balanced outputs.

  24VDC POWER

        The DX8 can be powered using a 24V DC power 

supply. This can serve as the primary power 

supply for the DX8, or as a backup supply 

in case of an AC power failure. The DX8 

seamlessly switches to the backup supply if 

there’s a power loss. When both AC power 

and 24V DC power are connected, the AC 

power is used and no current is drawn from 

the DC supply.

N/C

GROUND

N/C

LOGIC OUT 10
LOGIC OUT 9
LOGIC OUT 8
LOGIC OUT 7
LOGIC OUT 6
LOGIC OUT 5
LOGIC OUT 4
LOGIC OUT 3
LOGIC OUT 2
LOGIC OUT 1

N/C
LOGIC IN 10
LOGIC IN 9
LOGIC IN 8
LOGIC IN 7
LOGIC IN 6
LOGIC IN 5
LOGIC IN 4
LOGIC IN 3
LOGIC IN 2
LOGIC IN 1
+5VDC

LOGIC I/O

1

14

25

13

INPUT 1 HOT (+)

SIGNAL RETURN
SIGNAL RETURN
SIGNAL RETURN
SIGNAL RETURN
SIGNAL RETURN
SIGNAL RETURN
SIGNAL RETURN

INPUT 2 HOT (+)
INPUT 3 HOT (+)
INPUT 4 HOT (+)
INPUT 5 HOT (+)
INPUT 6 HOT (+)
INPUT 7 HOT (+)
INPUT 8 HOT (+)

DIRECT OUTPUTS