background image

4

 – CXA240

CXA240 – 

5

3. FRONT PANEL FEATURES

1.  LED INDICATORS

      PROT

This LED is on when the amplifier is in protection mode. 

This can occur if the volume is too high for long periods, or 

if heavy loads, a speaker defect, or poor ventilation cause 

the amplifier to overheat. If this light comes on, turn down 

your input signal to avoid over-working the amplifier, and 

check your speakers and wiring for defects. Check that the 

amplifier is also receiving good ventilation.

      SIGNAL

This LED is on when an input signal is present.

      PEAK

This LED comes on when the input signal is high and the 

maximum output is reached. Turn down the input signal if 

this LED comes on often.

2.  LED METER

This meter shows the signal output level. 

The lower eight LEDs represent the area between –20 dB 

and 0 dB. Adjust the volume to keep your output within 

these levels.

Turn down the volume level so the top two LEDs do not 

light, otherwise the outgoing signal will clip and distort.

3.  POWER

Use this rocker switch to turn the unit on or off. This 

connects/disconnects the AC power to the AC power 

transformer.

The amplifier is on when the top of the switch is pressed 

in. It is off when the bottom of the switch is pressed in.

POWER

OUTPUT

CXA240 - AMPLIFIER

PEAK

PROT

SIGNAL

DC FUSE

CAUTION : SHOCK HAZARD-DO NOT OPEN

RISK OF FIRE-REPLACE FUSE AS MARKED.

RISK OF ELECTRIC SHOCK

DO NOT OPEN

GND

FUSE

OFF

ON

IV/10K BAL.

DC POWER

LINE

LEVEL

ADJUST

TO REDUCE THE RISK
OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE
THIS APPARATUS TO 
RAIN OR MOISTURE. 
RISK OF HAZARDOUS 
ENERGY! MAKE PROPER 
SPEAKER CONNECTION. 
SEE INSTRUCTIONS 
BEFORE USING!

WARNING

INPUT

6.3AL 250V

MANUFACTURED  IN  CHINA      ©  2004  LOUD  TECHNOLOGIES  INC.

"EAW"  IS  A  REGISTERED  TRADEMARK  OF  LOUD  TECHNOLOGIES  INC.

COM

COM

70V

100V

4

OUTPUT

DC

24V

CAUTION

CXA240 - AMPLIFIER

115VAC/230VAC~ 60Hz/50Hz

115VAC/230VAC~ 60Hz/50Hz

1

1

5

FUSE

FU

SE

FU

SE

PUSH

PUSH

1

2

3

Summary of Contents for CXA240

Page 1: ...T TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE RISK OF HAZARDOUS ENERGY MAKE PROPER SPEAKER CONNECTION SEE INSTRUCTIONS BEFORE USING WARNING INPUT 6 3A...

Page 2: ...h This switch is located on the front panel and should remain readily accessible to the user WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture WARNI...

Page 3: ...z determined by a rear panel voltage select switch and is supplied by a detachable IEC power cord A rear panel terminal strip connection is provided for connecting an external 24 VDC backup battery wi...

Page 4: ...rn down the volume level so the top two LEDs do not light otherwise the outgoing signal will clip and distort 3 POWER Use this rocker switch to turn the unit on or off This connects disconnects the AC...

Page 5: ...e DC rail supply to the power amplifier Make sure that the AC supply is turned off before removing the fuse When you are sure that all is safe press in the fuse cover and turn it counter clockwise Rep...

Page 6: ...ransformer with an input voltage equal to that of the line 70 V or 100 V Make sure that the sum of the power capacities of the speakers does not exceed 90 of the amplifier s rated output power 216 W C...

Page 7: ...The two inputs are summed to mono Use balanced connections where possible instead of RCA unbalanced connections as these offer better rejection of noise Use high quality three conductor shielded cabl...

Page 8: ...heatsink Leave at least one rack space above and below and at least 6 inches behind the chassis to allow proper ventilation If the amplifier should overheat a thermal switch turns off the power ampli...

Page 9: ...CXA240 9 7 TYPICAL HOOKUP DIAGRAM CXA240 AMPLIFIER F U S E F U S E F U S E MIXER OR PREAMPLIFIER EAW DX810 MIXER AMPLIFIER EAW CAM150...

Page 10: ...5 50 60 Hz 24 VDC battery Power Consumption 486 W Physical Dimensions HxWxD 6 1 in 156 mm x 19 0 in 483 mm x 14 5 in 368 mm Including Feet Weight 34 1 lb 15 5 kg Warranty 5 years parts and labor DISCL...

Page 11: ...nty LOUD Technologies Inc requires its authorized EAW Commercial distributors to abide by the following warranty terms for all EAW Commercial brand products all dates are from the date of delivery fro...

Page 12: ...ies Inc Company EAW Commercial One Main Street Whitinsville MA 01588 USA TEL toll free within US Canada 888 337 7404 TEL outside US 425 892 6503 FAX 425 485 1152 www eawcommercial com 2004 LOUD Techno...