1. SAFETY INSTRUCTIONS

1. 

Read these instructions.  

2. 

Keep these instructions.

3. 

Heed all warnings.

4. 

Follow all instructions.

5. 

Do not use this apparatus near water.

6. 

Clean only with a dry cloth.

7.

  Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions.

8.

  Do not install near any heat sources such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat.

9.

  Do not defeat the safety purpose of the polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the other. A 

grounding-type plug has two blades and a third grounding prong. The 

wide blade or the third prong are provided for your safety. If the provided 

plug does not fit into your outlet, consult an electrician for replacement 

of the obsolete outlet.

10.

  Protect the power cord from being walked on or pinched particularly at 

plugs, convenience receptacles, and the point where they exit from the 

apparatus.

11.

  Only use attachments/accessories specified by the manufacturer.

12.

  Use only with a cart, stand, tripod, bracket, or table specified by the 

manufacturer, or sold with the apparatus. When a cart is used, use 

caution when moving the cart/apparatus combination to avoid injury from 

tip-over.

13.

  Unplug this apparatus during lightning storms or when unused for long 

periods of time.

14.

  Refer all servicing to qualified service personnel. Servicing is required 

when the apparatus has been damaged in any way, such as power-supply 

cord or plug is damaged, liquid has been spilled or objects have fallen 

into the apparatus, the apparatus has been exposed to rain or moisture, 

does not operate normally, or has been dropped.

15.

  This apparatus shall not be exposed to dripping or splashing, and no 

object filled with liquids, such as vases or beer glasses, shall be placed 

on the apparatus.

16. 

Servicing — The user should not attempt to service the Component 

beyond those means described in this operating manual. All other 

servicing should be referred to the EAW Commercial Service Department.

TABLE OF CONTENTS

1. SAFETY INSTRUCTIONS ...................................................

. INTRODUCTION ..................................................................3

  FEATURES  ...........................................................................3

  APPLICATIONS ...................................................................3

3. FRONT PANEL FEATURES .................................................4

4. REAR PANEL FEATURES ....................................................5

5. THERMAL CONSIDERATIONS ........................................10

6. CONNECTIONS .................................................................10

7. TYPICAL HOOKUP DIAGRAM .........................................11 

8. SPECIFICATIONS ..............................................................1

  BLOCK DIAGRAM .............................................................13

9. SERVICE INFORMATION .................................................14

10. WARRANTY .....................................................................15

17. 

To prevent electric shock, do not use this polarized plug with an 

extension cord, receptacle or other outlet unless the blades can be fully 

inserted to prevent blade exposure.

Pour prévenir les chocs électriques ne pas utiliser cette fiche polariseé 

avec un prolongateur, un prise de courant ou une autre sortie de 

courant, sauf si les lames peuvent être insérées à fond sans laisser 

aucune pariie à découvert.

18. 

Grounding or Polarization — Precautions should be taken so that the 

grounding or polarization means of the unit is not defeated. 

19. 

This apparatus does not exceed the Class A/Class B (whichever is 

applicable) limits for radio noise emissions from digital apparatus as set 

out in the radio interference regulations of the Canadian Department of 

Communications.

ATTENTION —Le présent appareil numérique n’émet pas de bruits 

radioélectriques dépassant las limites applicables aux appareils 

numériques de class A/de class B (selon le cas) prescrites dans le 

règlement sur le brouillage radioélectrique édicté par les ministere des 

communications du Canada.

WARNING! This equipment has been designed to be installed 

by qualified professionals only! There are many factors to be 

considered when installing professional sound reinforcement 

systems, including mechanical and electrical considerations, as 

well as acoustic coverage and performance. EAW Commercial 

strongly recommends that this equipment be installed only by a 

professional sound installer or contractor.

Part No. 0022185 Rev. B  03/07 
© 2007 LOUD Technologies Inc.  All Rights Reserved.  
Printed in China.

CAUTION    AVIS

RISK OF ELECTRIC 

SHOCK • DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER-SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

ATTENTION: POUR EVITER LES RISQUES DE CHOC

ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE.  AUCUN

ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER.  CONFIER

L'ENTRETIEN AU PERSONNEL QUALIFIE.

AVIS: POUR EVITER LES RISQUES D'INCENDIE OU

D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE 

A LA PLUIE OU A L'HUMIDITE

   The lightning flash with arrowhead symbol within an equilateral triangle is 

intended to alert the user to the presence of uninsulated "dangerous voltage" 

within the product's enclosure, that may be of sufficient magnitude to constitute 

a risk of electric shock to persons.

   Le symbole éclair avec point de flèche à l'intérieur d'un triangle équilatéral est 

utilisé pour alerter l'utilisateur de la présence à l'intérieur du coffret de "voltage 

dangereux" non isolé d'ampleur suffisante pour constituer un risque d'éléctrocution.

   The exclamation point within an equilateral triangle is intended to alert the user 

of the presence of important operating and maintenance (servicing) instructions 

in the literature accompanying the appliance.

   Le point d'exclamation à l'intérieur d'un triangle équilatéral est employé pour 

alerter les utilisateurs de la présence d'instructions importantes pour le fonction-

nement et l'entretien (service) dans le livret d'instruction accompagnant l'appareil.

Summary of Contents for CXA160 / CXA80

Page 1: ...CXA160 CXA80 Integrated Amplifiers INSTRUCTION MANUAL...

Page 2: ...c un prolongateur un prise de courant ou une autre sortie de courant sauf si les lames peuvent tre ins r es fond sans laisser aucune pariie d couvert 18 Grounding or Polarization Precautions should be...

Page 3: ...rate from 100 VAC to 240 VAC 50 60Hz supplied by a detachable IEC power cord Rear panel terminals are provided for connecting an external 24 VDC backup battery with automatic switching if the AC mains...

Page 4: ...above 10 kHz Turn it counter clockwise to cut the level In the detented center position there is no change in level The maximum boost and cut is 12 dB 3 VOLUME Use this volume control to adjust the so...

Page 5: ...red indicator LED will light 3 dB before clipping With normal source material playing adjust the pot until the LED lights only occasionally during the loudest moments of your program 10 Input DIP swi...

Page 6: ...adjust the pot until the LED lights only occasionally during the loudest moments of your program 15 Priority DIP switch This five pole DIP switch allows you to configure all four priority input types...

Page 7: ...led and GND accept the positive negative and ground terminals of a balanced audio line Secure the connections with the screws 21 Low Cut Filter Press this button in to engage the low cut filter on the...

Page 8: ...V 70 V or 100 V output terminal to the side of the speaker system and connect the upper GND output terminal to the side of the speaker system The voltage of your speakers must equal the voltage of th...

Page 9: ...plifier to be powered using 24 VDC emergency power supplies The unit will automatically switch to external DC battery power if your local AC power fails You will need to connect an external 24 Volt ba...

Page 10: ...hin a standard 19 rack The unit still needs to be supported underneath due to the weight of the power and output transformers 6 CONNECTIONS The Input and Priority Input use a dual purpose input connec...

Page 11: ...CXA80 11 7 TYPICAL HOOKUP DIAGRAM AM FM Tuner or CD Player Paging Microphone Line level output to the input of another CXA160 for example 70V Loudspeakers AC Line Backup Battery 24 VDC Paging Priority...

Page 12: ...VAC to 240 VAC 50 60Hz 200W AC Input Low Voltage Detector threshold 70 of Nominal Line Physical Specifications Height Excluding Feet 3 46 in 88 mm Width Overall 19 00 in 483 mm Depth Rear side of Rac...

Page 13: ...le XLR TRS Combo INPUT PRIORITY Screw Terminal Phoenix Connector High Pass Pad Enable 10 dB Trim Trim HIGH PASS PRIORITY REMOTE VOLUME LOW EQ HIGH EQ AMPLIFIER MONITOR BOARD OUTPUTS 4 OHM 25V 70V 100V...

Page 14: ...W Commercial Tech Support at support eawcommercial com 2 Pack the unit in its original packaging THIS IS VERY IMPORTANT LOUD Technologies is not responsible for any damage that occurs during shipping...

Page 15: ...for parts or labor if the warranty applies Final determination of warranty coverage lies solely with each authorized EAW Commercial distributor What Is Not Covered This warranty does not extend to da...

Page 16: ...ies Inc Company EAW Commercial One Main Street Whitinsville MA 01588 USA TEL toll free within US Canada 888 337 7404 TEL outside US 425 892 6503 FAX 425 485 1152 www eawcommercial com 2007 LOUD Techno...