![EAW Adaptive Seres Application Manual Download Page 31](http://html1.mh-extra.com/html/eaw/adaptive-seres/adaptive-seres_application-manual_527498031.webp)
30
low frequencies. With Adaptive systems, the array’s total output is available wherever coverage is
defined. In the examples below, both ‘full-coverage’ and ‘reduced-coverage’ options are presented. In
the ‘reduced-coverage’ scenario, SPL in the coverage zone is increased because the entire array is now
being applied to a smaller area.
System Components
56 Anya Modules (2x 16+12 modules)
32 Otto Modules (4x 8 modules)
4 Otto Flybars
4 Anya Flybars
8 Adaptive Distro Racks
Accessory Cabling Package
Predicted Performance
Average SPL: 107 dB (continuous)
Variation: +/- 2 dB
Rigging Requirements
(6) 2-ton motors*- Anya
(4) 1-ton motors - Otto
* Assumes two 2-ton motors for each 16-module Anya column.