EATON xChargeIn UDP Programmers Guide V 2.01
EATON xChargeIn, UDP Programmers Guide V 2.01
12
© EATON 2018
Field
Contents
Additional Description
Backend
0
No backend communication is present.
1
Backend communication is present.
timeQ
0
Not synced time (for more information see
“setdatetime”).
X
Strong synced time (for more information see
“setdatetime”).
2
Weak synced time (for more information see
“setdatetime”).
Sec
uint32
Current state of the system clock in seconds
from the last startup of the device.
3.2.3
UDP command: report 2
Command structure
Command
Parameters
Additional Description
report 2
-
-
Reply structure
Field
Contents
Additional Description
ID
2
ID of the report
State
0
Startup
1
Not ready for charging
Charging station is not connected to a
vehicle, is locked by the authorization
function or another mechanism.
2
Ready for charging and waiting for reaction
from vehicle.
3
Charging
4
Error is present
5
Charging process temporarily interrupted
because temperature is too high or any
other voter denies.
Error1
uint16
Decimal number defining the error
Error2
uint16
Decimal number defining the error