background image

4

Section I – Operating Characteristics 

“A” End

9-cylinder, variable delivery axial

. . . . . . . . . . . . . . . 

piston type pump

“B” End

9-cylinder, fixed displacement axial

. . . . . . . . . . . . 

piston type motor

Port Connections
(MTR3 & PTR3)

AND10050-8 (3/4-16)

. . . . . . . . . . . . . . . . . 

Operating Fluid:
    Type

Use petroleum oil SAE 20-20W API, MS.

. . . . . . . . 

Type “A” automatic transmission oil is

also permissible.

    Capacity

9/10 quart

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Maximum Displacement

0.645 cu.in per revolution

. . . . . . . 

Maximum Gauge Pressure

500 psi

. . . . . . . . . . . . . . . . . . . . 

Input (“A” End Drive) Speed:
    Maximum

1800 rpm

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

    Minimum

1200 rpm

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Output (“B” End Drive) Speed:
    Maximum

1800 rpm

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

    Minimum

100 rpm

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Pump Delivery:
    1800 rpm and 500 psi

4.7 gpm

. . . . . . . . . . . . . . . . . . . . . . 

    1200 rpm and 500 psi

3.1 gpm

. . . . . . . . . . . . . . . . . . . . . . 

Horsepower Ratings:
    Maximum input

1.50 @ 1800 rpm

. . . . . . . . . . . . . . . . . . . 

    Maximum output

1.12 @ 1750 rpm

. . . . . . . . . . . . . . . . . . 

Pump Yoke Control

Servo, Handwheel or Lever

. . . . . . . . . 

Direction of Rotation

Optional

. . . . . . . . . . . . . . . . . . . . . . . . . 

Mounting Position

Optional

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

(see nameplate)

Drive Connections

Direct or Indirect

. . . . . . . . . . . . . . . . . . . . 

Shaft Diameter

0.500 in.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Shaft Key

1/8 in. square

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Section II – Installation 

Adjustable speed hydraulic drives are precision built units
and should be treated as such. Careful attention to these
instructions will insure that maximum service life will be
obtained. For installation dimensions, the following drawings
should be referred to:

Model Number

Installation Drawing

TR3

I-259217

MTR3

I-214338

PTR3

I-214337

A. Mounting Position 

These units can be mounted in any position, provided the
filler cup is above the highest level of the unit (see name-
plates). Also, in the case of the motor units, the drain line
must be connected to the reservoir in such a manner that the
case remains full of fluid.

B. Control Position 

An optional handwheel or servo control can be mounted on
either side of the variable speed drive or pump. (Model
number codes for the type control and location are shown in
Table 1.) The handwheel control can be moved to the
opposite side of the unit if it is desired.

C. Coupling 

Conventional flexible couplings may be used, or these units
may be coupled indirectly through flat or vee belts, chain
drives or gears. If direct coupling is used (see Figure 1), the
shafts must be aligned accurately for maximum service life.
For indirect drive, the pulley, sheave, sprocket, or gear pitch
diameter must be at least 2 inches.

CAUTION

Couplings or pulleys must be assembled to the
shafts by hand. If a pulley or coupling becomes
tight after operation, a wheel puller should be used
to remove it. Pounding will cause damage to the
shaft and bearings. Keys must not be pounded into
the shaft keyways. Material can be removed by
lapping to fit the keys to the shafts.

Two keys are taped to each shaft (see Figure 2). The
stepped section keys are for units replacing -13 design units,
which used #4 Woodruff keys. For new installations, the
square section keys should be used.

Summary of Contents for Vickers MTR3

Page 1: ...I 1820 S Revised 9 1 87 Adjustable Speed Hydraulic Drives TR3 PTR3 and MTR3 Series 20 Design Overhaul Manual Vickers Transmissions ...

Page 2: ...2 EEaton Hydraulics Incorporated 2000 All Rights Reserved ...

Page 3: ...ation 4 A Mounting Position 4 B Control Position 4 C Coupling 4 D Circuit Connection 6 E Power Source 6 F Load 6 G Direction of Rotation 6 III Operation 7 A Fluid Recommendations 7 B Start up 7 C Handwheel Control 7 D Servo Control 7 IV Maintenance and Repair 7 V Warranty 8 ...

Page 4: ... Mounting Position These units can be mounted in any position provided the filler cup is above the highest level of the unit see name plates Also in the case of the motor units the drain line must be connected to the reservoir in such a manner that the case remains full of fluid B Control Position An optional handwheel or servo control can be mounted on either side of the variable speed drive or p...

Page 5: ...trol H Handwheel D Servo V None B End Control 13 13 32 Cylinder Bore B Fixed End Control F Fixed Table 1 Model Code Breakdown 4 Design 5 5 A End Size 13 13 32 Cylinder Bore Transmission 8 Motor 3 4 1 2 5 1 2 Motors Series 3 4 HP Design Size 13 13 32 Cylinder Bore 4 3 5 Pump 3 4 1 2 5 1 2 Pumps Series 3 4 HP Design Control Location viewed from shaft end opposite shaft R Right hand L Left hand 4 3 5...

Page 6: ...tors can either be used in a closed circuit supercharged at 30 psi or in an open circuit with a means of maintaining 30 psi back pressure at the outlet E Power Source This should be an 1150 1800 rpm electric motor or equivalent The source must supply 1 4 horsepower more than the required output F Load The maximum load which may be driven by these units is 3 4 horsepower The 40 inch pounds of torqu...

Page 7: ...t 90 to the direction of controlling efforts The control arm requires a 20 angular movement to change the output shaft speed from zero speed to full speed or a 40 angular movement from full speed in one direction to full speed in the opposite direction The maximum angular movement of the control arm must not exceed 20 each side of neutral It is not recommended that the control arm be actuated whil...

Page 8: ...he article is placed in service or a period of 180 days from the date the article is delivered by us whichever period first expires Unless otherwise stated on the face of our quotation or agreed by us in writing the foregoing sets forth our entire liability on warranties express or otherwise In no event will we be liable for special or consequential damages Form No 00 000 Copyright Eaton Corporati...