OPERATION

The Sure-Lites Eagle Eye Self Diagnostics is continuously
monitoring your emergency 

 xture, and will signal any

failure through the 3 color indicator LED.

INITIAL OPERATION

When the unit is 

 rst powered up, it will go into a 24 hour

fast charge, indicated by the indicator LED pulsing green.
Once the unit has fully charged, it will perform a self calibration,
after which the LED will change to steady green,
indicating the unit is fully charged and 

 oat charging the

battery to maintain readiness.

AUTOMATIC TESTING

The unit will perform a battery capacity, lamp/LED, and
charge circuit test every 30 days for 30 seconds. During
this time, the indicator LED will change to a steady yellow.
It will perform a full battery capacity (90 minute) test once
per year. During this time, the indicator LED will change to
a blinking yellow.

MANUAL TESTING

 

10 Second “Installation” test – Press and release the 
test button once during fast charge (blinking green) to 
initiate a 10 second quick test. The sign will switch to 
emergency mode for 10 seconds allowing the installer 
to verify proper installation of the unit, and the LED 
indicator will turn solid yellow.

 

30 Second Test - Press and release the test button once 
during

 oat charge (steady green). The indicator LED will 

turn steady yellow to indicate the unit is performing a 30 
second test of the batteries and lamps/LEDs.

 

90 Minute Test - Press and release the test button a 
second time during a 30 second test (steady yellow) to 
change to a 90 minute test. During this test, the LED indi-
cator will change to blinking yellow, and the circuit will per-
form a full battery capacity, charge circuit, and LED test.

 

Cancelling Test – Press and release the test button 
during the 90 minute test (

 ashing yellow) to return the 

 xture to its original state (fast charge or 

 oat charge).

LASER TEST

The SELDWTA29SD/SELDWA50SD/ATLELDWTA100SD/
ATLELDWA300SD series is equipped with a Laser Test 
function, that allows the unit to be manually tested without 
the need to physically press the test button. Shining a laser 
pointer in the hole marked “LASER TEST” on the bottom of
the unit has the same effect as a press and release of the 
test button.     

CLEARING FAILURE CODES

 

A battery failure (LED two blink red) can be cleared by 
replacing the battery. Disconnecting the battery and AC 
power, or performing a full 90 minute discharge, will reset 
the error code, however, it will return if the battery is faulty.

 

Charge Circuit (LED three blink red) and lamp/LED failure 
(LED four blink red) will clear when the unit successfully 
passes a manual or automatic 30 second test.

INDICATORS

LED Off - No power to unit, emergency mode.

LED Steady Green - Unit is fully charged and is 

 oat charging 

the battery to maintain readiness.

LED Green Pulse - Unit is in a 24 hour fast charge of the bat-
tery.

LED Two Blink Red - Battery has failed a capacity test, or the 
battery is disconnected. See “Clearing Failure Codes” above.

LED Three Blink Red - Battery charge circuit has failed. See 
“Clearing Failure Codes” above.

LED Four Blink Red - Lamps have burned out, or on an EXIT/
Combo, 50% or more of the LEDs have failed. See “Clearing 
Failure Codes” above.

LED Steady Yellow - 30 second test or 10 second quick test 
(Fast Charge only).

LED Blinking Yellow - 90 minute test

MAINTENANCE

None required. Replace the batteries as needed according
to ambient conditions. Equipment should be tested every
30 days in accordance with local codes.

NOTE: Servicing of any parts should be performed by quali

ed personnel. Only use replacement parts supplied by Eaton
Lighting. Use of unauthorized parts may void the warranty.

CAUTION: This equipment is furnished with a sophisticated
low voltage battery disconnect to protect the battery
from over discharge after its useful output has been used.
Allow 24 hours recharge time after installation or power
failure prior to 90 minute testing.

TROUBLE SHOOTING GUIDE

1.  If LED heads or charge indicator LED does not illuminate, 

check the following:

2.  Check AC supply – verify that unit has 24 hour AC supply.

3.  Unit is shorted or battery is not connected.

4.  Battery discharged. Permit unit to charge for 24 hours and 

then re-test.

5.  If following the above trouble shooting hints does not solve 

your problem, contact your local Eaton Lighting represen-
tative for assistance