Chapter 10: View Log Menu
The control unit keeps a log of events (for example, alarms and times of setting/unsetting).
An installer or master user can read the log when the system is completely unset. Note
that no other user type can read the log.
Log Events
To comply with EN50131-1:2006 for grade 2 systems, the log is divided internally into two
portions: mandatory events and non-mandatory events. The installer can view either of
these lists separately, or see all log events in one list. Additionally, the EN 50136 Log
stores SPT events to comply with this standard. Please refer to Appendix C on page 66 for
a description of each log message.
Mandatory events are those that are recorded to comply with EN 50131. Non-mandatory
events are other events not needed to comply with EN 50131.
The entire log stores its records for at least 10 years without power.
The first three events of the same type (e.g. tamper alarms) that occur in the same unset
or set period are logged in the mandatory log. Any further events of that type are logged in
the non-mandatory log.
When you are viewing a log event, pressing
may display additional information.