Appendix A: Log Messages
Introduction
This Appendix gives short explanations of the messages that may appear in the control
unit’s log.
Please note that many of the messages refer to specific devices by the bus and device
number. Therefore, it is not possible to show in this list the exact log message that you
may be seeing on any given installation.
The list itself is sorted alphabetically by the text of the message. In the column “Event Log
Text” you will see “==” or sometimes “#”. These characters stand in for the zone, user or
device number that the control unit has recorded for the event being logged. In the
“Description” column this is shown as “n”.
Log messages
Event Log Text
(Scantronic)
Description
"== Ex Keys Rstr"
Excess keys (code attempts)
tamper restore
"24hr Z=== Alarm"
24 hour alarm on zone n
"24hr Z=== Restore"
24 hour alarm on zone n restored
"A/C Fail"
AC mains failed and was
communicated
"A/C Restore"
AC mains was restored
"Alarm Abort U--"
Alarm aborted by user n
"Alarm Conf ==ER"
Alarm has been confirmed by a
missing external prox reader on
keypad n
"Alarm Conf Bell #"
Confirmed alarm with tamper on
Bell n
"Alarm Conf. =="
Confirmed alarm with tamper on
keypad n
"Alarm Confirm Z=="
Confirmed alarm on zone
"Alarm Confirm"
Confirmed alarm
"Alm Conf Bus# Tamp"
An alarm was confirmed by a bus
tamper
"Alm Conf Panel Lid"
Confirmed alarm with tamper on
control unit lid
"ATE L.F. All"
All lines to alarm transmission
equipment failed
"ATE L.F. Restore"
Line to alarm transmission
equipment restored
"ATE L.F. Single"
Alarm transmission equipment has
a single line fault
"Auxiliary 12V Fail"
Control unit 12V Aux DC not
working
"Auxiliary 12V Rstr"
Control unit 12V Aux DC restored
"Bad checksum"
There is an error on loading the
control unit with its software
"Batt = Fault Rst"
Control unit battery restored
"Batt = Low/Missing"
Control unit battery missing or low
"Bell # 12V Fail"
12V DC supply to bell n failed
"Bell # 12V Restore"
12V DC supply to bell n restored
"Bell # Tamper Rstr"
External wired siren n tamper
restored
"Bell # Tamper"
External wired siren n tamper
"Burg Z== Alarm"
Burglar alarm on zone n
"Burg Z== Restore"
Burglar alarm on zone n restored
"Burg Z=== Alarm"
Burglar on First linked zone n in
Beam Group
"Burg Z=== Restore"
Burglar on First linkedzone n in
Beam Group restored
"Bus # 12V Fail"
12V DC supply to Bus n failed
"Bus # 12V Restore"
12V DC supply to Bus n restored
"Bus # Tamper Rstr"
Bus n has been restored
"Bus # Tamper"
Bus n has been tampered (for
example wires cut or disconnected)
"Codes Defaulted"
All access codes were returned to
factory defaults
"Configuration Fail"
The current configuration is not
compatible with the software
revision level of the control unit
"Defaults Loaded"
The control unit was returned to
factory defaults
"Disabled =="
Keypad n disabled
"Dup. == Restore"
Duplicate keypad restored
"Duplicate =="
Duplicate keypad n detected
"Enabled =="
Keypad n enabled
"Entry Started Z=="
Entry started by zone n