2 Engineering
2.12 Motor and application
72
Rapid Link 5 · RAMO5 · RASP5
05/20 MN034004EN
www.eaton.com
Figure 32:
Example for eccentric drive
a
upper break point
b
lower break point
2.12.5 Interlocked manual operation
Interlocked manual operation prevents damage to conveyed goods or the
equipment through incorrect handling. Limit switches connected to inputs I1
and I2, for example, can be used to reliably limit the travel path. This function
also allows adjustment of, for example, light barriers before automatic con-
trol through a PLC (AS-Interface) is activated.
Figure 33:
Interlocked manual operation
a
Internal response time
b
Selector switch in Manual mode
c
Output signal
As shown in Figure 33, the FWD rotating field direction is disabled in Manual
mode when interlocked manual operation is activated after a rising edge (on
I1, for example) with a continuous signal. The motor can then be operated in
Manual and Auto mode with an opposite direction of rotation in RAMO5-W
and RASP5 units.