Eaton PowerXL DM1 Series Instruction Leaflet Download Page 10

10

Instruction Leaflet 

PUB53675

Effective June 2020

PowerXL DM1 and DM1 Pro series VFD 

  

  

EATON

 www.eaton.com

FR3 mounting instructions

Step 1. 

Lift the drive out from the carton, remove the packaging.  The 

magnetic cores and cable ties are only included in EMI version drive.

Step 2. 
Screw mounting:

 Attach the drive to the mounting plate with four 

M5X20 (or 3/16 in.) screws and four M5 (or 3/16 in.) nuts.  The 

opening dimension on the mounting plate should follow required 

dimension (refer to the dimension drawing in the instruction leaflet).

DIN Rail mounting:

 Lift the drive at an angle about 30 degrees.  

Align the top hooks of drive DIN rail mounting slot with DIN rail top 

edge.  Push down and rotate the drive to clip the bottom hooks on 

the bottom DIN rail edge.

Step 3. 

(EMI version only):

The input wires (including three line wires and one input grounding 

wire)  should run through the input magnetic core before connecting 

to input terminal block and grounding hole.  Use a cable tie to tie the 

input magnetic cores to the input wires.
For 3-phase FR3 EMI version, the output wires (only three motor 

wires) should run through the output magnetic core before connect-

ing to output terminal block.  The output grounding wire should not 

run through the output magnetic core.  Use a cable tie to tie the 

output magnetic cores to the output wires.  For 1-phase FR3 EMI 

version, there is no output magnetic core.  The motor wires and 

output grounding wire can be connected to corresponding terminals 

directly.
The maximum distance between input / output magnetic cores top 

surface and drive bottom surface is 100 mm.
The input magnetic core and output magnetic core are the same for 

3-phase FR3 EMI version.

+

Screw mounting

Four M5x20 or 3/16 inch screws

Four M5 or 3/16 inch nuts

Torque: 3 N.m (26.6 lb/in.)

DIN Rail mounting

3 line wires

Input grounding wire

Output grounding wire

Max. distance: 100 mm (3.94 in.)

3 motor wires

Input magnetic core

Output magnetic core

Summary of Contents for PowerXL DM1 Series

Page 1: ...el ctrica Peligro de muerte El trabajo a continuaci n descrito debe ser realizado por personas cualificadas y advertidas Tensione elettrica Pericolo di morte Solo persone abilitate e qualificate poss...

Page 2: ...isk m ek rt m instru t s personas Pavojus gyvybei d l elektros srov s Tik elektrikai ir elektrotechnikos specialistai gali atlikti emiau apra ytus darbus Pora enie pr dem elektrycznym stanowi zagro en...

Page 3: ...00 hp 7D8 7 8 A 1 50 kW 2 00 hp 5D6 5 6 A 2 20 kW 3 00 hp 013 13 5 A 7 50 kW 10 00 hp 011 11 0 A 2 20 kW 3 00 hp 011 11 0 A 2 20 kW 3 00 hp 7D6 7 6 A 3 00 kW 5 00 hp 018 18 0 A 11 00 kW 15 00 hp 017...

Page 4: ...207 4 29 109 3 56 90 5 3 56 90 5 0 22 5 5 5 7 2 6 FR3 DM1 12017 17 5 25 3 7 09 180 10 24 260 9 72 247 5 12 130 4 57 116 4 57 116 0 22 5 5 8 2 3 7 200 Vac to 240 Vac 50 60 Hz 3 phase FR1 DM1 321D6 1 6...

Page 5: ...34016 16 23 7 09 180 8 66 220 8 15 207 4 29 109 3 56 90 5 3 56 90 5 0 22 5 5 5 7 2 6 FR3 DM1 34023 23 31 7 09 180 10 24 260 9 72 247 5 12 130 4 57 116 4 57 116 0 22 5 5 8 2 3 7 FR4 DM1 34031 31 38 7 6...

Page 6: ...0 1 97 50 1 97 50 14 83 25 2 FR2 DM1 127D8 7 8 11 0 0 1 97 50 1 97 50 24 72 42 DM1 12011 11 17 5 0 0 1 97 50 1 97 50 24 72 42 FR3 DM1 12017 17 5 25 3 0 0 1 97 50 1 97 50 42 37 72 200 Vac to 240 Vac 5...

Page 7: ...0 37 43 63 6 DM1 34012 12 16 0 0 1 97 50 1 97 50 37 43 63 6 DM1 34016 16 23 0 0 1 97 50 1 97 50 37 43 63 6 FR3 DM1 34023 23 31 0 0 1 97 50 1 97 50 58 61 99 6 FR4 DM1 34031 31 38 0 0 1 97 50 1 97 50 57...

Page 8: ...3 EMI version only The input wires including 3 line wires and 1 input grounding wire should run through the input magnetic core before connecting to input terminal block and grounding hole Use a cabl...

Page 9: ...Four M5 or 3 16 inch nuts Torque 3 N m 26 6 lb in Step 3 EMI version only The input wires including 3 line wires and 1 input grounding wire should run through the input magnetic core before connecting...

Page 10: ...ough the input magnetic core before connecting to input terminal block and grounding hole Use a cable tie to tie the input magnetic cores to the input wires For 3 phase FR3 EMI version the output wire...

Page 11: ...input magnetic core before connecting to input terminal block and grounding hole Use a cable tie to tie the input magnetic cores to the input wires The output wires only 3 motor wires should run thro...

Page 12: ...en remove the termi nal cover 2 from drive For open type Only remove the terminal cover Step 2 Remove the option card port label and four snap covers from the drive 2 1 Enclosed type Open type Step 3...

Page 13: ...pen type Only install the terminal cover to the drive Wiring instruction 2 Enclosed type Open type 1 Termination resistor dip switch ON 120 termination resistor On Off 120 termination resistor Off 1 3...

Page 14: ...vain j nnitteett m ss tilassa Varov n P ipojujte jen p i zcela odpojen m nap jen Hoiatus hendada ainult pingevabas olekus Figyelmeztet s Csak fesz lts gmentes llapotban csatlakoztassa Br din jums Pies...

Page 15: ...5 1 2 10 6 7 1 0 8 28 16 0 5 1 5 1 73 0 2 4 5 0 5 DM1 116D9 6 9 7 8 10 6 10 5 1 2 10 6 7 1 0 8 28 16 0 5 1 5 1 73 0 2 4 5 0 5 200 Vac to 240 Vac 50 60 Hz 1 phase FR1 DM1 121D6 1 6 2 5 14 2 5 4 4 0 5...

Page 16: ...2 4 5 0 5 DM1 34016 16 23 8 10 10 5 1 2 10 10 7 1 0 8 28 16 0 5 1 5 1 73 0 2 4 5 0 5 FR3 DM1 34023 23 31 8 10 10 5 1 2 8 10 14 2 1 6 28 16 0 5 1 5 1 73 0 2 4 5 0 5 FR4 DM1 34031 31 38 6 16 33 3 73 8...

Page 17: ...2 7 20 1 40 30 25 30 10 10 20 6 12 8 DM1 32017 17 5 25 3 20 1 29 1 60 40 32 45 8 10 20 6 12 8 FR3 DM1 32025 25 3 32 2 29 1 37 70 50 40 50 8 8 20 6 10 8 FR4 DM1 32032 32 2 48 3 35 4 53 1 100 80 4 8 20...

Page 18: ...7 20 1 40 30 25 30 6 6 0 5 16 4 0 10 DM1 32017 17 5 25 3 20 1 29 1 60 40 32 45 10 10 0 5 16 4 0 10 FR3 DM1 32025 25 3 32 2 29 1 37 70 50 40 50 10 10 0 5 16 6 0 10 FR4 DM1 32032 32 2 48 3 35 4 53 1 10...

Page 19: ...19 Instruction Leaflet PUB53675 Effective June 2020 PowerXL DM1 and DM1 Pro series VFD EATON www eaton com Installation overview for DM1 2 DM1 L1 L2 L3 R R U V W...

Page 20: ...TO2 17 STO1 18 RY1NO 19 RY1CM 20 RY1NC 21 RY2NO 22 RY2CM 8 AI1 9 AI1 10 GND 11 AO1 12 GND 13 10 V 14 24 V 1 DIN1 2 DIN2 3 DIN3 4 DIN4 5 CMA 6 A 7 B Relay terminals I O terminals 18 RY1NO 19 RY1CM 20 R...

Page 21: ...I O signal ground I O ground for reference and control 11 AO1 Analog output 1 Output frequency Shows output frequency to motor 0 60 Hz 4 mA to 20 mA 12 GND I O signal ground I O ground for reference a...

Page 22: ...beh r kun tages i anvendelse hvis det konstateres at maskinen opfylder beskyttelseskravene i maskindirektivet 89 392 E F EMC korrekt installation Tr k styre og netledninger rumligt adskilt fra motorle...

Page 23: ...no krmiljenih naprav in njihovega pribora dovoljen le tedaj ko je bilo ugotovljeno da stroj ustreza varnostnim zagtevam Direktive o strojih 89 392 EGS Monta a v skladu z EMZ Krmilne in omre ne vodnik...

Page 24: ...bsite www eaton com drives www eaton eu electrical www eaton com cn electrical Email VFDaftermarketEG eaton com AfterSalesEGBonn eaton com CustomerServicePDCNA eaton com Phone 1 877 386 2273 8 00 a m...

Page 25: ...ld not be discarded together with un separated household waste but must be collected separately The product should be handed in for recycling in accordance with the local environmental regulations for...

Page 26: ...26 Instruction Leaflet PUB53675 Effective June 2020 PowerXL DM1 and DM1 Pro series VFD EATON www eaton com Notes...

Page 27: ...27 Instruction Leaflet PUB53675 Effective June 2020 PowerXL DM1 and DM1 Pro series VFD EATON www eaton com Notes...

Page 28: ...ton and the purchaser THERE ARE NO UNDERSTANDINGS AGREEMENTS WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY S...

Reviews: