COMPLETING THE INSTALLATION:
1. Install the sensor loosely using the mounting screws provided.
2. Apply power temporarily and verify that the sensor works by pushing the ON/OFF
button to verify the control load can operate properly (i.e. lights can turn on and off).
In the case of controlling a Switchpack, skip STEP 3 altogether.
3. If the lights do not work, then turn off the power and swap the connections on the
sensor black and red wires. Apply power again and verify that the sensor works by
pushing the ON/OFF button to verify the lights turn on and off.
4. Turn power to the device OFF.
5. Secure sensor into the wall box using two mounting screws provided. Turn the
circuit breaker ON.
6. Allow the sensor to stabilize for 30 seconds. The sensor is now ready to detect
motion.
7. Verify that Power is ON by pushing the ON/OFF button. Lights should turn ON.
8. NOTE - The sensor time delay is factory preset (5 minutes).
9. If you want to change the time delay proceed as follows:
a. Remove the button from the sensor by pressing in
the
hooks on the button, and then lift up on the button
as
shown in Fig. 4.
b. Set the time delay using the dial on the right side by
using a small Phillips screwdriver. Align the arrow on
the dial to desired time delay. See Fig. 5.
c. To allow the installer to quickly confirm that the sensor
is functioning properly the time delay can be set to
TEST. This will set a time delay of 5 seconds, which
allows quick feedback that the sensor is work-
ing
properly.
10. Replace push button by sliding it upward into the slots in
the front housing and push down until the button hook
snaps into place.
11. Push the ON/OFF button to verify that the lights turn ON/
OFF, and that the button operates freely.
12. Install the wallplate.
Daylight Sensing Adjustment:
• The Daylight sensing feature prevents lights
from
turning ON when the room is adequately illuminat-
ed
by natural light.
• NOTE - The factory setting for this adjustment is
fully
clockwise and permits motion detection to turn ON
the lights regardless of the ambient light level in the
room.
• Remove the ON/OFF pushbutton to access the light
level adjustment. See Fig. 4.
• This adjustment must be made when the light level
in
the room is at the desired level for the lights to
turn
ON.
• From the clockwise position, turn the dial on the left
counterclockwise using a small Phillips screwdriver
until the LED starts to flash. See Fig. 5.
• Step away from the sensor to allow the
device
to
calibrate to the normal light level in the room.
Do not obstruct the natural light. The calibration
process starts when the LED and lights turn
OFF,
and
will take approximately 15 seconds. After completion
the lights will turn on.
• Replace the ON/OFF pushbutton.
TROUBLESHOOTING:
If you have a problem with your Motion Sensor, first follow this guide. If the problem persists, call the customer service hotline at 1-866-853-4293 between 8:00 A.M. and 6:00 P.M. EST
weekdays.
SYMPTOM
POSSIBLE CAUSE
SOLUTION
.
Light does not automatically turn on.
1. Circuit breaker is turned off, or fuse is blown.
1. Turn circuit breaker on, or replace fuse.
2. Bulb is defective.
2. Replace light bulb.
3. Poor connection.
3. Verify all wiring connections.
4. Control may be wired incorrectly.
4. Check wiring.
5. Daylight sensing prevents lights on
5. Re-adjust daylight sensing level.
6. Manual On mode selected
6. Set device to Automatic On mode.
.
Light does not automatically turn off.
1. Motion is still present.
1. Make sure there is no motion during the time delay period.
2. Time Delay has not expired.
2. No action needed or shorten TIME DELAY.
3. Control may be wired incorrectly.
3. Check wiring
4. Switch is being triggered by air vent or other heat source.
4. Move switch to the other switch location (if a 3-way), or determine the
source triggering the switch, and alter the air flow.
.
Light does not stay on
1. Motion is not detected.
1. Create movement in front of the sensor for 5 seconds.
2. TIME control is set for too short a delay
2. Set switch TIME control to longer time period.
.
Remote switch does not work
1. Control may be wired incorrectly.
1. Check wiring
EATON WIRING DEVICES LIMITED 2 YEAR WARRANTY
Eaton Wiring Devices (EWD) warrants this device to be free of defects in materials and workmanship in normal use and service for a period of two years from date of original purchase. THIS 2 YEAR LIMITED WARRANTY
IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS IN
DURATION IN EXCESS OF 2 YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF EWD HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF EWD
UNDER THIS WARRANTY.
To obtain warranty service for any properly installed EWD device that proves defective in normal use send the defective device prepaid and insured to Quality Control Dept., Eaton Wiring Devices, 203 Cooper Circle,
Peachtree City, GA 30269; in Canada: Eaton Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8.
EWD will repair or replace the defective unit, at its option. EWD will not be responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse, abuse, improper installation,
alteration, improper maintenance or repair of damage in shipment to EWD.
EWD SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE DEVICE, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL,
CONTINGENT, OR CONSEQUENTIAL DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE SYSTEM OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY
ON THIS PRODUCT.
Relay OUT
Red
Blue
3-Way
Traveler
Red
Black Traveler
Light
Fixture
White
First Location
Second Location
Neutral Traveler
DIAGRAM 2B: SENSOR IN LOCATION WITH HOT WIRE
3-Way
Switch
Ground
120/277V
Hot
Black
Ground
Bare
Green
Relay IN
Orange
Hot
Black
White
120/277V
Black Traveler
DIAGRAM 3: SENSORS IN BOTH LOCATIONS
Light
Fixture
Red Traveler
White
Neutral
3-Way
Blue
3-Way
Blue
Relay OUT
Red
Black
Relay OUT
Red
120/277V
Ground
Bare
Green
Relay IN
Orange
Black Traveler
Ground
Bare
Green
Relay IN
Orange
Hot
Black
120/277V
Hot
Black
120/277V
Hot
Black
Black Traveler
1. PRESS TO
RELEASE
HOOK
FIGURE 4
2. LIFT UP
BUTTON
LIGHT LEVEL
T
ES
T
5 10
30
TIME DELAY
TURN TO SET
FIGURE 5:
www.eaton.com
www.eaton.com/wiringdevices
EIS-0156-E (REV.A)