background image

MTL9466-ET 

 

Managed Ethernet Switch 

September 2016
INM 9466 rev 3 

Instruction manual

MTL intrinsic safety solutions

Summary of Contents for MTL9466-ET

Page 1: ...MTL9466 ET Managed Ethernet Switch September 2016 INM 9466 rev 3 Instruction manual MTL intrinsic safety solutions ...

Page 2: ...ATION OF CONFORMITY A printed version of the Declaration of Conformity has been provided separately within the original shipment of goods However you can find a copy of the latest version at http www mtl inst com certificates ...

Page 3: ...ATING WITH THE 9466 ET 4 6 1 In the safe area 4 6 2 In the hazardous area 4 7 LAUNCHING THE PROGRAM 4 8 MAIN SCREEN 5 8 1 Menu Bar 5 9 VLAN 6 10 RATE LIMIT 7 11 MIRRORING 8 12 MIB COUNTERS 9 13 STATIC MAC ADDRESSES 9 14 DYNAMIC MAC ADDRESSES 10 15 DOWNLOADING NEW SOFTWARE 10 16 ENVIRONMENTAL 11 17 WASTE REMOVAL INFORMATION 11 18 ACCESSORIES 11 19 APPROVALS 12 20 FM CERTIFICATION INFORMATION 12 21 ...

Page 4: ...iv INM9466 rev 3 THIS PAGE IS LEFT INTENTIONALLY BLANK ...

Page 5: ... cables Broadcast storm protection eliminates network overload caused by excessive broadcast and multicast packets Intelligent Routing Automatic address learning aging and migration Supports IEEE 802 3 10Base T 100Base TX IEEE 802 1q Tag Port based VLAN Quality of Service QoS priority Programmable Managed features Serial port VLAN Rate Limiting Port Mirroring etc DIN rail mounting module Note PoEx...

Page 6: ...a the serial RS232 TTL port either in the Safe Area using a PC or in the Hazardous Area using the 9461 ET Ethernet Gateway as its host processor Features such as Programmable Rate Limiting VLAN support Port Mirroring and Forced Speed and Duplex settings may be configured in this way if required The 9461 ET module can also perform its usual function of a serial communications gateway eg serial Modb...

Page 7: ...connection 6 12V dc in PoEx Port 1 see Note 2 7 0V 8 12V dc in PoEx Port 2 see Note 2 9 0V 10 12V dc in PoEx Port 3 see Note 2 11 0V 12 12V dc in PoEx Port 4 see Note 2 13 0V 14 12V dc in PoEx Port 5 see Note 2 15 0V Note 1 Terminals 1 2 and 3 4 are linked internally 2 For PoEx connect IS supplies to terminals 6 to 15 as required WARNING The supply for PoEx must be derived from a suitably certifie...

Page 8: ...ch the installation program In either case this is a conventional installation program that requires the user to specify a destination directory for the application software after which the setup will continue Follow the on screen instructions to complete the installation 6 COMMUNICATING WITH THE 9466 ET 6 1 In the safe area Connect the 9466 ET Ethernet Switch to your PC using the CAB9466 RS commu...

Page 9: ...n times out after approximately 5 minutes After modifications are made they need to be sent or saved to the switch Sending to the switch is only temporary and will be lost on a power down whereas saving is permanent Also on this and every page is the status bar at the bottom This records the last event that has happened Events can include Switch Offline Settings Saved or Sent etc 8 1 Menu Bar At t...

Page 10: ... ET supports 16 active VLANs Any one of the 4096 available VLAN ID s can be specified as one of the active VLANs If a non tagged packet or a null VID packet is received the 9466 ET will use the ingress ports programmable default VID for look up Click Enabling Value Editing and enter the password In order to use the 802 1Q VLAN it must be enabled by selecting the Enabled 802 1Q VLAN checkbox As can...

Page 11: ...be programmed up to the line rate in increments of 32 768 bps On the above screen the rates can be set in Mbps for both low and high priority messages To limit High priority messages ensure the Disable Priority check boxes are not selected The rate limits can be enabled by selecting the check boxes on the appropriate limit The priority for each port can be set to be Diffser 802 1P Port Based or No...

Page 12: ... s Transmit only port mirroring Information transmitted on a port can be mirrored to another port s Receive and Transmit port mirroring Information received on a port and information transmitted on a port can be mirrored to another port s Specify the port s by checking the boxes for the ports In the first column Mirror Port you specify the ports to receive the mirrored information then check boxes...

Page 13: ...TIC MAC ADDRESSES The 9466 ET offers 8 static MAC settings These can be allocated a VLAN ID or set at 0 to allow MAC lookup Click Enabling Value Editing and enter the password The port to forward the messages for the static MAC can be selected and whether or not to override the spanning tree Static MACs can be activated or deactivated using the checkbox on the far right These settings can easily b...

Page 14: ...SOFTWARE The 9466 ET has the facility to upgrade its software To begin this action select the Update Switch Software menu bar option which will bring up the password dialog box After password entry a file selection window will appear Select the software file you wish to load into the 9466 ET Switch and click the Open button The following warning will appear on screen Click No if you need to return...

Page 15: ... of correctly you will be helping to prevent potentially negative consequences for the environment and human health which could otherwise be caused by incorrect waste handling of this product For more detailed information about the take back and recycling contact Eaton s MTL product line 18 ACCESSORIES For interconnecting the 9460 ET range of products we offer approved RJ45 Cat5e UTP cables in var...

Page 16: ...g chemical vapours of the Ketone or Ester families 21 ATEX IECEx CERTIFICATION INFORMATION The following information is in accordance with the Essential Health and Safety Requirements Annex II of the EU Directive 2014 34 EU the ATEX Directive safety of apparatus and is provided for those locations where the ATEX Directive is applicable General a This equipment must only be installed operated and m...

Page 17: ...ure shall also comply with the requirements of Clauses 7 and 8 of EN 60079 0 2006 2 The connectors do not meet the ingress protection rating of IP20 therefore this shall be taken into consideration during the installation of the 9400 Series Ethernet Modules when used with Group II gases and each module shall be provided with an enclosure that is commensurate with the environment into which it is i...

Page 18: ...14 INM9466 rev 3 Replace this page with the first page of the PDF of the Control Drawing ...

Page 19: ...15 INM9466 rev 3 Replace this page with the second page of the PDF of the Control Drawing ...

Page 20: ...ia No 36 Nehru Street Off Old Mahabalipuram Road Sholinganallur Chennai 600 119 India Tel 91 0 44 24501660 24501857 Fax 91 0 44 24501463 E mail mtlindiasales eaton com ITALY MTL Italia srl Via San Bovio 3 20090 Segrate Milano Italy Tel 39 02 959501 Fax 39 02 95950759 E mail chmninfo eaton com JAPAN Cooper Crouse Hinds Japan KK MT Building 3F 2 7 5 Shiba Daimon Minato ku Tokyo Japan 105 0012 Tel 81...

Reviews: