DB3BM SOUNDER TECHNICAL MANUAL

  

TM277.3

  www.eaton.com

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY

The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation’s 

(“Eaton”) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales 

office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in 

appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser.
THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING 

WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE  

SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE 

ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY 

ANY CONTRACT BETWEEN THE PARTIES. 
In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or 

other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to 

damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the 

use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the 

information, recommendations and descriptions contained herein. The information contained in this manual is subject to 

change without notice.

FRANCAIS

Les informations, des recommandations, des descriptions et des notations de sécurité dans ce document sont basés 

sur Eaton Corporation de ( “Eaton”) expérience et le jugement et peuvent ne pas couvrir toutes les éventualités. Si des 

informations supplémentaires sont nécessaires, un bureau de vente Eaton devrait être consulté. La vente du produit 

indiqué dans cette littérature est soumise aux termes et conditions appropriées décrites dans Eaton à vendre des polices 

ou accord contractuel other Entre Eaton et l’acheteur.
IL N’Y A PAS ENTENTES, ACCORDS, GARANTIE, EXPLICITE OU IMPLICITE, Y COMPRIS LES GARANTIES D’ADAPTATION 

À UN USAGE PARTICULIER OU DE COMMERCIALISATION, AUTRES QUE CEUX SPECIFIES DANS TOUT CONTRAT 

EXISTANT ENTRE LES PARTIES. UN TEL CONTRAT ETATS L’OBLIGATION ENTIER DE EATON. LE CONTENU DE CE 

DOCUMENT NE DOIT PAS DEVENIR PARTIE OU MODIFIER TOUT CONTRAT ENTRE LES PARTIES.
En aucun cas, Eaton responsable à l’acheteur ou de l’utilisateur dans le contrat, en responsabilité délictuelle (y compris 

la négligence), la responsabilité stricte ou autre sage pour tout dommage spécial, indirect ou consécutif ou toute perte, 

y compris mais sans s’y limiter les dommages ou pertes d’utilisation de l’équipement, installation ou du système 

d’alimentation, le coût du capital, perte de puissance, les dépenses supplémentaires dans l’utilisation des installations 

électriques existantes, ou des réclamations contre l’acheteur ou de l’utilisateur par ses clients résultant de l’utilisation des 

informations, des recommandations et des descriptions contenues dans les présentes. Les informations contenues dans 

ce manuel sont sujettes à modification sans préavis.

Summary of Contents for MEDC DB3BM

Page 1: ...Sounder DB3BM Eaton MEDC technical manual ...

Page 2: ...tained in this manual is subject to change without notice FRANCAIS Les informations des recommandations des descriptions et des notations de sécurité dans ce document sont basés sur Eaton Corporation de Eaton expérience et le jugement et peuvent ne pas couvrir toutes les éventualités Si des informations supplémentaires sont nécessaires un bureau de vente Eaton devrait être consulté La vente du pro...

Page 3: ...tion 4 General safety messages and warnings 4 Installation 5 Access to terminals 5 Wiring details 5 Operation 9 Tone table 1 Standard tones 10 Tone table 2 Volt free tone selection 11 General arrangement 12 Maintenance 13 Certification approvals 14 Special conditions for safe use 14 ...

Page 4: ...diagram in this manual or separate diagram provided with the unit viii Ensure that only the correct listed or certified cable glands are used and that the assembly is shrouded and correctly earthed ix Ensure that only the correct listed or certified stopping plugs are used to blank off unused gland entry points in accordance with EN IEC60079 14 clauses 16 3 16 4 16 5 and that the NEMA IP rating of...

Page 5: ...ximum gap of 0 025mm is maintained between the cover and the base once assembled To maintain the IP rating of the unit the recommended torque on the cover screws is 3 0Nm Wiring details The unit is available in a number of basic configurations 1 AC input single stage 2 AC input dual stage with voltage free stage selection 3 DC input up to 3 user selectable stages without monitoring 4 DC input up t...

Page 6: ...erminals 3 wire system Dual stage common ve Connect 3 supply wires to the terminals as detailed in the wiring diagram 2 ve wires and 1 common ve wire Stage 1 is produced when power is applied across the stage 1 ve and common ve terminals Stage 2 is produced when power is applied across the stage 2 ve and common ve terminals 4 wire system Triple stage Common ve Connect 4 supply wires to the termina...

Page 7: ...e stage common ve configuration or if an optional EOL is specified if can be configured as a dual stage common ve system with monitoring 4 wire system Triple stage Common ve Connect 4 supply wires to the terminals as detailed in the wiring diagram 1 common ve wire and 3 ve wires Stage 1 is produced when power is applied across the common ve and stage 1 ve terminals Stage 2 is produced when power i...

Page 8: ...d remote switches to terminals R0 to R5 as shown When the switch connected to R1 is closed the stage 1 tone will be produced as selected by the 5 way DIP switch on the electronics assembly When any of the other switches connected to R2 to R5 is closed the pre selected tone for stages 2 to 5 are produced See tone table 2 for details of pre selected tones ote N Closing more than one switch at a time...

Page 9: ...s The unit is fitted with a volume control which is positioned on the top face of the electronics assembly PCB Maximum volume is obtained when this control is turned fully clockwise When turned fully anti clockwise the unit will emit no sound WARNING Do not attempt to turn the volume control past its limits of movement as this may cause damage to the unit WARNING The unit has a certified upper ope...

Page 10: ... Hz for 0 4S 10001 French Fire Sound 104 16 Int 660 Hz 150 mS on 150 mS off 10000 Swedish Fire Alarm 104 17 Int 660 Hz 1 8 sec on 1 8 sec off 01111 Swedish Fire Alarm 104 18 Int 660 Hz 6 5 sec on 13 sec off 01110 Swedish Fire Alarm 104 19 Continuous 660 Hz 01101 Swedish Fire Alarm 105 20 Alt 554 440 Hz at 1 Hz 01100 Swedish Fire Alarm 104 21 Int 660 Hz at 7 8 Hz 01011 Swedish Fire Alarm 105 22 Int...

Page 11: ...50Hz at 1Hz 10100 T14 T10 T1 T8 T14 13 970Hz at 1 4 sec on 1 sec off 10011 T14 T10 T1 T8 T14 14 Continuous at 970Hz 10010 T28 T10 T1 T8 T28 15 554Hz for 0 1S 440Hz for 0 4S 10001 T14 T10 T1 T8 T14 16 Int 660Hz 150 mS on 150 mS off 10000 T14 T10 T1 T8 T14 17 Int 660Hz 1 8 sec on 1 8 sec off 01111 T14 T10 T1 T8 T14 18 Int 660Hz 6 5 sec on 13 sec off 01110 T14 T10 T1 T8 T14 19 Continuous 660Hz 01101 ...

Page 12: ...12 Manuel technique Eaton MEDC DB3BM SOUNDER TECHNICAL MANUAL TM277 3 www eaton com GENERAL ARRANGEMENT ...

Page 13: ... details below are not intended to be repaired Corrosion inhibiting grease such as petrolatum or soap thickened mineral oils may be applied to flameproof joint surfaces before assembly The grease if applied shall be of a type that does not harden because of ageing does not contain an evaporating solvent and does not cause corrosion of the joint surfaces Verification of suitability shall be in acco...

Page 14: ...uitability for use in surface industries 2 Signifies suitability for use in a Zone 1 area G Signifies suitability for use in the presence of gasses D Signifies suitability for use in the presence of dust T Ratings Max Power rating Tamb TG TD 15W 60 C to 85 C 60 C to 55 C 60 C to 40 C T4 T5 T6 T135 C T100 C T85 C These units also have the following approvals Ingress protection Long Flare units IP66...

Page 15: ...15 Eaton MEDC technical manual DB3BM SOUNDER TECHNICAL MANUAL TM277 3 www eaton com Notes ...

Page 16: ...ertissements d ordre général 17 Installation 18 Accès aux bornes 18 Détails du câblage 18 Fonctionnement 22 Tableau des sons 1 sons standard 23 Tableau des sons 2 sélection des sons hors tension 24 Disposition générale 25 Maintenance 26 Certification approbations 27 Conditions particulières pour une utilisation en toute sécurité 27 ...

Page 17: ...u schéma fourni avec l appareil viii Assurez vous que seuls les presse étoupes correctement répertoriés ou certifiés sont utilisés et que l ensemble est protégé et correctement mis à la terre ix Assurez vous que seuls les bouchons correctement répertoriés ou certifiés sont utilisés pour obturer les points d entrée de presse étoupes non utilisés conformément aux clauses EN CEI 60079 14 16 3 16 4 et...

Page 18: ...vercle et la base une fois l appareil assemblé Pour maintenir l indice de protection IP de l appareil il est recommandé de serrer les vis du couvercle au couple de 3 0 Nm Détails du câblage L appareil est disponible dans un certain nombre de configurations de base 1 Entrée CA une seule phase 2 Entrée CA deux phases avec sélection de la phase hors tension 3 Entrée CC jusqu à 3 phases sélectionnable...

Page 19: ...câblage 2 fils positifs et 1 fil commun négatif La phase 1 est produite lorsque l alimentation est appliquée sur la borne positive de la phase 1 et sur la borne commune négative La phase 2 est produite lorsque l alimentation est appliquée sur la borne positive de la phase 2 et sur la borne commune négative Système à 4 fils trois phases fil commun négatif Connectez 4 fils d alimentation aux bornes ...

Page 20: ... en option est spécifiée en tant que système commun négatif à deux phases avec contrôle Système à 4 fils trois phases fil commun positif Connectez 4 fils d alimentation aux bornes comme indiqué sur le schéma de câblage 1 fil commun positif et 3 fils négatifs La phase 1 est produite lorsque l alimentation est appli quée sur la borne commune positive et sur la borne négative de la phase 1 La phase 2...

Page 21: ... sélection effectuée sur le commutateur DIP 5 voies sur l ensemble électronique Lorsque l un des autres interrupteurs connectés à R2 à R5 est fermé les sons présélectionnés pour les phases 2 à 5 sont produits Reportez vous au tableau des sons 2 pour en savoir plus sur les sons présélectionnés ote N La fermeture de plusieurs interrupteurs à la fois entraîne l absence de son Si une résistance R1 est...

Page 22: ...lume située sur la face supérieure de la carte de circuit imprimé de l ensemble électronique Le volume maximal est obtenu lorsque cette commande est tournée à fond dans le sens des aiguilles d une montre Lorsqu elle est tournée à fond dans le sens inverse des aiguilles d une montre l appareil n émet aucun son AVERTISSEMENT n essayez pas de tourner la commande de volume au delà de ses butées car vo...

Page 23: ...incendie pour la Suède 104 17 Intermittent 660 Hz pendant 1 8 s aucun son pendant 1 8 s 01111 Alarme incendie pour la Suède 104 18 Intermittent 660 Hz pendant 6 5 s aucun son pendant 13 s 01110 Alarme incendie pour la Suède 104 19 Continue 660 Hz 01101 Alarme incendie pour la Suède 105 20 Alternant 554 440 Hz à 1 Hz 01100 Alarme incendie pour la Suède 104 21 Intermittent 660 Hz à 7 8 Hz 01011 Alar...

Page 24: ... T1 T8 T14 14 Continue à 970 Hz 10010 T28 T10 T1 T8 T28 15 554 Hz pendant 0 1 s 440 Hz pendant 0 4 s 10001 T14 T10 T1 T8 T14 16 Intermittent 660 Hz pendant 150 ms aucun son pendant 150 ms 10000 T14 T10 T1 T8 T14 17 Intermittent 660 Hz pendant 1 8 s aucun son pendant 1 8 s 01111 T14 T10 T1 T8 T14 18 Intermittent 660 Hz pendant 6 5 s aucun son pendant 13 s 01110 T14 T10 T1 T8 T14 19 Continue 660 Hz ...

Page 25: ...UBLES ET SUPPORT STANDARD 186 5 2 50 5 1 78 2 267 4 3 197 3 48 1 78 2 ORIFICE DE FIXATION Ø 13 1 TROUS DE FIXATION Ø 9 1 2 POSITIONS Ø 200 2 Ø 145 5 2 Ø 148 2 30 1 30 1 2 ENTRÉES MAX 18 18 25 25 25 VERSION EN ACIER INOXYDABLE À ÉVASEMENT COURT Ex d AVEC ENTRÉE SIMPLE ET SUPPORT PIVOTANT TOUTES LES DIMENSIONS SONT COMMUNES AUX DEUX MATÉRIAUX SAUF INDICATION CONTRAIRE ...

Page 26: ... les huiles minérales épaisses au savon ou au pétrolatum peut être appliquée sur les surfaces des joints antidéflagrants avant l assemblage La graisse si elle est appliquée doit être de type non durcissant au fil du temps ne doit pas contenir de solvant pouvant s évaporer et ne doit pas causer de corrosion sur les surfaces des joints Vérifiez si la graisse est appropriée en consultant les spécific...

Page 27: ...ns les industries de surface 2 Indique la compatibilité pour une utilisation dans une Zone 1 G Indique la compatibilité pour une utilisation en présence de gaz D Indique la compatibilité pour une utilisation en présence de poussière Caractéristiques nominales T Puissance max Tamb TG TD 15 W de 60 C à 85 C de 60 C à 55 C de 60 C à 40 C T4 T5 T6 T135 C T100 C T85 C Ces unités sont également dotées d...

Page 28: ...28 Manuel technique Eaton MEDC MANUEL TECHNIQUE DE LA SIRÈNE DB3BM TM277 3 www eaton com Remarques ...

Page 29: ...ed in this document and to prices are reserved so are errors and omissions Only order confirmations and technical documentation by Eaton is binding Photos and pictures also do not warrant a specific layout or functionality Their use in whatever form is subject to prior approval by Eaton The same applies to Trademarks especially Eaton Moeller and Cutler Hammer The Terms and Conditions of Eaton appl...